Purpose To develop and assess a full‐coverage, sensitivity encoding (SENSE)‐accelerated breast high spatial and spectral resolution (HiSS) magnetic resonance imaging (MRI) within clinically reasonable times as a potential nonenhanced MRI protocol for breast density measurement or breast cancer screening. Materials and Methods Sixteen women with biopsy‐proven cancer or suspicious lesions, and 13 women who were healthy volunteers or were screened for breast cancer, received 3T breast MRI exams, including SENSE‐accelerated HiSS MRI, which was implemented as a submillimeter spatial resolution echo‐planar spectroscopic imaging (EPSI) sequence. In postprocessing, fat and water resonance peak height and integral images were generated from EPSI data. The postprocessing software was custom‐designed, and new algorithms were developed to enable processing of whole‐coverage axial HiSS datasets. Water peak height HiSS images were compared to pre‐ and postcontrast T 1 ‐weighted images. Fat suppression was quantified as parenchymal‐to‐suppressed‐fat signal ratio in HiSS water peak height and nonenhanced T 1 ‐weighted images, and artifact levels were scored. Results Approximately a 4‐fold decrease in acquisition speed, with a concurrent 2.5‐fold decrease in voxel size, was achieved, with low artifact levels, and with spectral signal‐to‐noise ratio (SNR) of 45:1. Fat suppression was 1.9 times more effective ( P 0.001) in HiSS images than in T 1 ‐weighted images (SPAIR), and HiSS images showed higher SNR in the axilla. HiSS MRI visualized 10 of 13 malignant lesions identified on dynamic contrast‐enhanced (DCE)‐MRI, and did not require skin removal in postprocessing to generate maximum intensity projection images. Conclusion We demonstrate full‐coverage, SENSE‐accelerated breast HiSS MRI within clinically reasonable times, as a potential protocol for breast density measurement or breast cancer screening. Level of Evidence: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1341–1348.
机译:目的在临床上合理的时间内开发和评估全覆盖,灵敏度编码(SENSE)-Accelerated乳房高空间和光谱分辨率(MRI)作为乳腺密度测量或乳腺癌筛选的潜在的非肤色型MRI方案。材料和方法具有活组织检查成熟的癌症或可疑病变的16名女性,以及13名女性是健康的志愿者或被筛查乳腺癌,接受了3T乳腺MRI考试,包括感觉加速的HIS MIRS,这是作为淹没空间分辨率回声所实施的-Planar光谱成像(EPSI)序列。在后处理中,从EPSI数据生成脂肪和水共振峰值高度和积分图像。后处理软件是定制设计的,开发了新的算法,以实现整个覆盖的轴向嘶嘶声数据集。将水峰高度Hiss图像与Pre-and Postcrast T 1 -weigutional的图像进行比较。脂肪抑制量被定量为Hiss水峰高度和非共育T 1 - 重量的图像中的实质抑制脂肪信号比,并评分伪像水平。结果采集速度下降大约4倍,voxel尺寸的同时的2.5倍降低,具有低伪像水平,并且光谱信噪比(SNR)为45:1。在Hiss映像中,脂肪抑制比在T 1 - 重量的图像(SPAIR)中的比例抑制为1.9倍(P <0.001),并且HIS图像在腋窝中显示出更高的SNR。 Hiss MRI可视化10个在动态对比增强(DCE)-MRI上识别的13个恶性病变,并且在后处理时不需要皮肤去除以产生最大强度投影图像。结论我们在临床上合理的时间内展示了全覆盖,感觉加速的乳房Hiss MRI,作为乳腺密度测量或乳腺癌筛选的潜在方案。证据水平:2技术疗效:第1阶段J. MANG。恢复。 2017年成像; 46:1341-1348。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号