首页> 外文期刊>Journal of medical ultrasonics: official journal of the Japan Society of Ultrasonics in Medicine >Application of shear wave elastography and B-mode ultrasound in patellar tendinopathy after extracorporeal shockwave therapy
【24h】

Application of shear wave elastography and B-mode ultrasound in patellar tendinopathy after extracorporeal shockwave therapy

机译:剪切波弹性造影和B模式超声在体外冲击疗法后髌骨肌腱病的应用

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose The purpose of this study was to investigate changes in morphological and elastic properties, as estimated by B-mode ultrasound (B-US) and shear wave elastography (SWE), in volleyball athletes with patellar tendinopathy (PT) and changes after extracorporeal shockwave therapy (ESWT) as well as their relationships with US measurements and Victorian Institute of Sport Assessment-Patella (VISA-P) scores in PT. Methods Twelve healthy athletes (24 patellar tendons) and 31 volleyball athletes with PT (48 tendons) were included. All were examined by US and received VISA-P scores before the start of the study. The athletes received 3 months of ESWT and underwent US and VISA-P at 1 month and 3 months. VISA-P scores were used to evaluate therapeutic efficacy. Tendon thickness and cross-sectional area (CSA) were detected by B-US, and the elastic modulus was measured by SWE. Correlations between VISA-P and US measurements were calculated. Results Thickness, CSA, and elastic modulus of the patellar tendon in PT were higher than those in healthy athletes (P < 0.000). In PT with ESWT, VISA-P scores decreased by 22.1% (P < 0.000) and thickness decreased by 11.2% relative to baseline (P < 0.000). CSA decreased by 1.4% (P < 0.000). The elastic modulus decreased by 15.2% (P < 0.000). Elastic modulus, thickness, and CSA had significant negative correlations with VISA-P scores (P <= 0.005), with a stronger correlation between elastic modulus and VISA-P. Conclusion Athletes with PT had stiffer and larger tendons than healthy athletes. SWE combined with B-US could clearly show the changes in tendon thickness, CSA, stiffness in PT, and changes after treatment. SWE combined with B-US provided visualization with quantitative, reproducible, and noninvasive imaging in the follow-up evaluation of PT and is worth promoting clinically.
机译:目的本研究的目的是研究形态学和弹性性质的变化,如B模式超声(B-US)和剪切波弹性摄影(SWE)估计,排球运动员在具有髌骨肌腱病变(PT)和体外冲击波后变化治疗(ESWT)以及与美国测量和维多利亚体育运动程评估研究所 - 髌骨(Visa-P)的关系。方法包括十二名健康运动员(24个髌骨肌腱)和31名伴有PT(48个肌腱)的排球运动员。所有人都被美国审查并在研究开始前获得了签证分数。运动员在1个月和3个月内接受过3个月的ESWT并接受美国和签证P. Visa-P分数用于评估治疗效果。通过B-US检测肌腱厚度和横截面积(CSA),通过SWE测量弹性模量。计算Visa-P和美国测量之间的相关性。结果厚度,CSA和PT中PT的髌骨肌腱的弹性模量高于健康运动员(P <0.000)。在PT中,在ESWT中,Visa-P分数逐渐降低22.1%(P <0.000),相对于基线(P <0.000),厚度降低11.2%。 CSA减少1.4%(P <0.000)。弹性模量减少15.2%(P <0.000)。弹性模量,厚度和CSA与Visa-P分数具有显着的负相关性(P <= 0.005),弹性模量与Visa-p之间具有更强的相关性。结论PT的运动员比健康运动员更富有更硬,肌腱较大。 SWE与B-US相结合可以清楚地显示肌腱厚度,CSA,PT刚度的变化,以及治疗后的变化。 SWE与B-US相结合提供了在PT的后续评估中的定量,可重复和非侵入性成像的可视化,并且值得临床促进。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号