An alternative technology that surpasses the efficiency of conventional vapor compression cycle is necessary to meet the increasing demand for air conditioning. One of the candidates, membrane heat pump (MHP), can decrease energy consumption through the separation of the air-conditioning process into dehumidification and sensible heat cooling. Humid air is dehumidified through a vapor-permeable dense membrane and cooled by a water-cooling cycle. When dehumidifying, a vacuum membrane system can be utilized in the heat pump system. In this study, two typical systems, water vapor discharge and condenser-combined vacuum membrane dehumidification (VMD) systems, are elucidated, and MHPs that consist of each VMD system are designed. Their performance are simulated and compared. The MHP with water vapor discharge VMD system has an improved coefficient of performance in general.
机译:需要一种超越常规蒸汽压缩循环效率的替代技术,以满足不断增加对空调的需求。 候选物,膜热泵(MHP)中的一种,可以通过将空调过程分离成除湿和明智的热冷却来降低能量消耗。 潮湿的空气通过气相透过致密膜来除湿,并通过水冷循环冷却。 当除湿时,可以在热泵系统中使用真空膜系统。 在该研究中,阐明了两个典型的系统,水蒸气放电和冷凝器组合的真空膜除湿(VMD)系统,并设计了由每个VMD系统组成的MHP。 它们的性能是模拟和比较。 具有水蒸气放电VMD系统的MHP具有改善的性能系数。