The purpose of this study was to evaluate the suitability of a novel radio-frequency identification (RFID)-based tracking system for intraoperative magnetic resonance imaging (MRI). A RFID tracking system was modified to fulfill MRI-compatibility and tested according to ASTM and NEMA. The influence of the RFID tracking system on MRI was analyzed in a phantom study using a half-Fourier acquisition single-shot turbospin echo (HASTE) and true fast imaging with steady-state precession sequence (TrueFISP) sequence. The RFID antenna was gradually moved closer to the isocenter of the MR scanner from 90 to 210 cm to investigate the influence of the distance. Furthermore, the RF was gradually changed between 865 and 869 MHz for a distance of 90 cm, 150 cm, and 210 cm to the isocenter of the magnet to investigate the influence of the frequency. The specific spatial resolution was measured with and without a permanent line of sight (LOS). After the modification of the reader, no significant change of the signal-to-noise ratio (SNR) could be observed with increasing distance of the RFID tracking system to the isocenter of the MR scanner. Also, different radio frequencies of the RFID tracking system did not influence the SNR of the MR-images significantly. The specific spatial resolution deviated on average by 8.97 +/- 7.33 mm with LOS and 11.23 +/- 12.03 mm without LOS from the reference system. The RFID tracking system had no relevant influence on the MR-image quality. RFID tracking solved the LOS problem. However, the spatial accuracy of the RFID tracking system has to be improved for medical usage.
机译:本研究的目的是评估用于术中磁共振成像(MRI)的新型射频识别(RFID)跟踪系统的适用性。修改RFID跟踪系统以满足MRI兼容性并根据ASTM和NEMA进行测试。使用半傅里叶采集单射汽轮素回声(急速)在幻影研究中分析了RFID跟踪系统对MRI的影响,以及具有稳态预测序列(TRUEFISP)序列的真正快速成像。 RFID天线从90到210厘米逐渐靠近MR扫描仪的ISOcenter,以研究距离的影响。此外,RF在865和869MHz之间逐渐变为90cm,150cm,210cm的距离,磁体的等中心以研究频率的影响。使用永久视线(LOS)测量特定的空间分辨率。在修改读取器之后,通过将RFID跟踪系统的距离增加到MR扫描仪的ISOcenter的距离,可以观察到信噪比(SNR)的显着变化。而且,RFID跟踪系统的不同射频频率不会显着影响MR图像的SNR。特定空间分辨率平均偏离8.97 +/- 7.33 mm,LOS和11.23 +/- 12.03 mm,没有LOS从参考系统。 RFID跟踪系统对MR图像质量没有相关影响。 RFID跟踪解决了LOS问题。然而,必须改善RFID跟踪系统的空间准确性以进行医疗用途。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号