首页> 外文期刊>Journal of laparoendoscopic and advanced surgical techniques, Part A >Clinical Usefulness of a Self-Retaining Internal Organ Retractor for Laparoendoscopic Single-Site Adrenalectomy
【24h】

Clinical Usefulness of a Self-Retaining Internal Organ Retractor for Laparoendoscopic Single-Site Adrenalectomy

机译:腹腔腔室内腔室肾上腺切除术自我保持内器牵开器的临床有用性

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Introduction: Although laparoendoscopic single-site adrenalectomy (LESS-A) is feasible, it is still considered as a challenging procedure because of technical limitations. Making an optimal retraction is one of major obstacles in LESS-A, and it sometimes requires additional ports or needlescopic devices. Internal organ retractor (IOR) is a novel retraction device that is applied intracorporeally without additional port. In this study, we investigated the clinical usefulness of IOR in LESS-A. Materials and Methods: Medical records of 73 consecutive patients who underwent LESS-A from March 2009 to December 2014 were reviewed. Twenty-two patients underwent LESS-A with IOR and 51 patients without IOR. Results: Mean age, body mass index, tumor size, operation time, estimated blood loss, and hospital stay were not significantly different between two groups. In IOR group, median number of applied IOR was 2.0 (1.0–3.0) per single operation. Mean time for application and removal was 80.0 and 46.5 seconds for a single IOR, respectively. There were no complications related to the IOR. In without IOR group, there were nine cases that needed needlescopic trocars, six cases that needed 5 mm or larger trocars, and one case that was converted to hand-assisted laparoscopy. However, we did not use any needlescopic instrument or additional trocar in IOR group. There was no case of open conversion in both groups. Conclusion: LESS-A could be done effectively and safely using IOR. IOR system maintained optimal retraction throughout the operation. Its application and removal are intuitive and take only a few minutes. We think IOR system is an attractive retraction method in LESS-A.
机译:介绍:虽然腹腔形态单位肾上腺切除术(少A)是可行的,但由于技术限制,它仍被视为有挑战性的程序。使最佳缩回是较少A的主要障碍之一,它有时需要额外的端口或无缝装置。内部器官牵开器(IOR)是一种新型缩回装置,其在没有额外端口的情况下施用。在这项研究中,我们调查了IOR在较少-A的临床有用性。材料与方法:审查了73名以2009年3月至2014年12月接受了较低的63名患者的医疗记录。二十二名患者接受了较少的A含量和51名没有IOR的患者。结果:平均年龄,体重指数,肿瘤大小,操作时间,估计血液损失,两组之间的病例没有显着差异。在IOR组中,应用IOR中位数为2.0(1.0-3.0)每次运行。单个IOR的应用和移除的平均时间分别为80.0和46.5秒。没有与IOR相关的并发症。在没有IOR组的情况下,有九个案例需要无缝轨道,六种案例需要5毫米或更大的轨道,以及转换为手工辅助腹腔镜检查的一个案例。但是,我们没有在IOR集团中使用任何无缝仪器或额外的套管针。两组都没有开放转换。结论:较少A可以使用IOR有效和安全地完成。 IOR系统在整个操作中保持最佳缩回。它的应用和删除是直观的,只需几分钟即可。我们认为IOR系统在较少-A中是一个有吸引力的缩回方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号