This article details the analysis of two conducting shafts operating on blowers of a tunnel dryer. A deductive analysis was applied looking toward a successful recognition of root cause(s), where based on knowledge of background, and failure characteristics, multiple hypothesis are exposed that are further confirmed or rejected according to different tests, material analysis or maintenance history. In both shafts, failure arises from inadequate repairing. In order to confirm this, the failure analysis methodology included the following steps: technical review, visual inspection, fractography, penetrating inks, metallography, optic microscopy and stress analysis. Evidence obtained through these techniques indicates a fatigue failure induced by inadequate repairing procedures; therefore, main recommendation is to take the necessary precautions in order to guarantee minimal alterations on shaft geometry or material microstructure.
机译:本文详细说明了在隧道烘干机的鼓风机上运行的两个导电轴的分析。 在努力认识到根本原因的成功识别,在基于背景的知识和失败特征的情况下,揭露了一些假设,根据不同的测试,材料分析或维护历史进一步确认或拒绝多个假设。 在两个轴中,由于修复不足而导致失败。 为了确认这一点,失败分析方法包括以下步骤:技术审查,视觉检查,断裂,穿透油墨,金相,光学显微镜和应力分析。 通过这些技术获得的证据表明修复程序不足引起的疲劳失败; 因此,主要推荐是采取必要的预防措施,以保证轴几何形状或材料微观结构的最小变化。