首页> 外文期刊>Journal of chromatography, B. Analytical technologies in the biomedical and life sciences >Development and application of a HILIC UHPLC-MS method for polar fecal metabolome profiling
【24h】

Development and application of a HILIC UHPLC-MS method for polar fecal metabolome profiling

机译:HILIC UHPLC-MS方法对极性粪便代谢分析的开发与应用

获取原文
获取原文并翻译 | 示例
           

摘要

The fecal metabolome is a complex mixture of endogenous, microbial metabolites, and food derived compounds. Hydrophilic interaction liquid chromatography (HILIC) enables the analysis of polar compounds, which is a valuable alternative to reversed-phase liquid chromatography in the field of metabolomics due to its ability to retain a greater portion of the polar metabolome. The objective of the study was to find the optimal chromatographic solution to perform non-targeted metabolomics of feces by means of HILIC ultra-high-pressure liquid chromatography mass spectrometry (UHPLC-Q-TOF-MS). The performance was systematically investigated analyzing a pooled fecal sample, and mixtures of 150 metabolites from different families, including for example amino acids, amines, indole derivatives, fatty acids and carbohydrates. Three different stationary phases (zwitterionic, amide and unbonded silica) were operated at three pH values (4.6, 6.8 and 9.0), and three salt gradient conditions (5-5, 5-10 and 5-25 mM ammonium acetate). Amide and zwitterionic stationary phases performed similarly at low pH, with highest number of detected standards, which increased by increasing the salt gradient. The amide column showed slightly better performance in terms of separation of isomers and peak widths and remarkably good performance at basic pH, with highest number of metabolite features in the non targeted analysis. The zwitterionic column operated best in terms of number of detected standards, retention time distribution of standards and metabolite feature across whole chromatographic run. Thus, the zwitterionic column was proven to suit for non-targeted analysis of fecal samples, resulting in good coverage of especially amino acids and carbohydrates.
机译:粪便代谢物是内源性,微生物代谢物和食品衍生化合物的复杂混合物。亲水性相互作用液相色谱(HILIC)能够分析极性化合物,这是由于其保留大部分偏离代谢物的能力而在代谢组科领域中反相液相色谱的有价值替代物。该研究的目的是通过HILIC超高压液相色谱质谱法(UHPLC-Q-TOF-MS),找到最佳的色谱溶液,以通过HILIC超高压液相色谱法质谱进行粪便非靶向代谢溶剂。系统地研究了分析汇集的粪便样品,以及来自不同家族的150个代谢物的混合物,包括例如氨基酸,胺,吲哚衍生物,脂肪酸和碳水化合物。在三个pH值(4.6,6.8和9.0)和三种盐梯度条件下(5-5,5-10和5-25mM乙酸铵)操作三个不同的固定相(两性离子,酰胺和未粘附二氧化硅)。酰胺和两性离子固定相在低pH下同样地进行,具有最多的检测标准,其通过增加盐梯度而增加。酰胺塔在异构体和峰宽度的分离方面表现出略微更好的性能,并且在碱性pH下具有显着性的性能,在非有针对性分析中具有最多的代谢物特征。在检测到的标准数量的数量,横跨整个色谱运行的标准标准数量,保留时间分布和代谢物特征的数量最佳。因此,已证明两性离子柱以适用于对粪便样品的非靶向分析,导致尤其是氨基酸和碳水化合物的良好覆盖。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号