首页> 外文期刊>Journal of Chromatographic Science >HPTLC Method for Determination of R, R-Glycopyrronium Bromide and its Related Impurities
【24h】

HPTLC Method for Determination of R, R-Glycopyrronium Bromide and its Related Impurities

机译:HPTLC法测定R,R-糖甘油溴化物及其相关杂质的测定

获取原文
获取原文并翻译 | 示例
       

摘要

An innovative high-performance thin layer chromatographic (HPTLC) method was designed, optimized and validated for the quantification of R, R-glycopyrronium bromide (GLY) and its related impurities in drug substance and drug product. Separation was performed on HPTLC plates pre-coated with silica gel 60 F-254 by dichloromethane:methanol:formic acid (10:0.5:0.5, v/v/v) as a developing system. GLY and its related impurities namely, glycopyrronium impurity G and glycopyrronium impurity J, were separated giving compact well-resolved spots with significant retardation factor (R-f) values of 0.17 +/- 0.02, 0.34 +/- 0.02 and 0.69 +/- 0.02, respectively. Quantification was done at 220 nm in the ranges of 0.3-10 and 0.2-4.0 mu g/spot with limits of detection and quantification of 0.1, 0.3 and 0.05, 0.2 mu g/spot for GLY and its related impurities, respectively. Good accuracy was obtained with mean percentage recovery of 99.48 +/- 1.36, 100.04 +/- 1.32 and 99.61 +/- 0.80 and R-2 >= 0.9968 for GLY and its impurities, consecutively. Validation parameters were presented according to the International Conference on Harmonization. The method was used to investigate impurity profile of GLY in drug substance and drug product and could be applied in routine analysis of the drug. Comparison between the developed method and the reported method revealed no statistical difference.
机译:设计,优化和验证了一种创新的高性能薄层色谱(HPTLC)方法,用于定量R,R-糖甘油溴化物(Gly)及其在药物物质和药物产品中的相关杂质。对通过二氯甲烷预涂覆的硅胶60f-254预涂覆的HPTLC板进行分离:甲醇:甲酸(10:0.5:0.5,v / v / v)作为显影系统。含量及其相关的杂质即,分离糖酮杂质G和糖酮杂质J,其具有显着延迟因子(RF)值的紧凑良好分辨的斑点为0.17 +/- 0.02,0.34 +/- 0.02和0.69 +/- 0.02,分别。定量在0.3-10和0.2-4.0μg/斑点的220nm下,分别具有0.1,0.3和0.05,0.2μg及其相关杂质的0.1,0.3和0.05,0.2μg/斑点的限制。在连续的情况下,使用平均百分比回收率为99.48 +/- 1.36,100.04 +/- 1.32和99.61 +/- 0.80和R-2> = 0.9968的良好精度。验证参数是根据国际协调会议提出的。该方法用于研究药物物质和药物产品中的GLY的杂质谱,并且可以应用于药物的常规分析中。显影方法与报告方法之间的比较显示没有统计差异。

著录项

  • 来源
  • 作者单位

    Natl Org Drug Control &

    Res NODCAR 51 Wezerat El Zeraa St St Agouza POB 12553 Giza 35521 Egypt;

    Natl Org Drug Control &

    Res NODCAR 51 Wezerat El Zeraa St St Agouza POB 12553 Giza 35521 Egypt;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 分析化学;
  • 关键词

  • 入库时间 2022-08-20 09:04:08

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号