A long-term durability test was conducted on a newly developed axial-flow ventricular assist device (VAD) with hydrodynamic bearings. The mock circulatory loop consisted of a diaphragm pump with a mechanical heart valve, a reservoir, a compliance tank, a resistance valve, and flow paths made of polymer or titanium. The VAD was installed behind the diaphragm pump. The blood analog fluid was a saline solution with added glycerin at a temperature of 37 A degrees C. A pulsatile flow was introduced into the VAD over a range of flow rates to realize a positive flow rate and a positive pressure head at a given impeller rotational speed, yielding a flow rate of 5 L/min and a pressure of 100 mmHg. Pulsatile flow conditions were achieved with the diastolic and systolic flow rates of similar to 0 and 9.5 L/min, respectively, and an average flow rate of similar to 5 L/min at a pulse rate of 72 bpm. The VAD operation was judged by not only the rotational speed of the impeller, but also the diastolic, systolic, and average flow rates and the average pressure head of the VAD. The conditions of the mock circulatory loop, including the pulse rate of the diaphragm pump, the fluid temperature, and the fluid viscosity were maintained. Eight VADs were tested with testing periods of 2 years, during which they were continuously in operation. The VAD performance factors, including the power consumption and the vibration characteristics, were kept almost constant. The long-term durability of the developed VAD was successfully demonstrated.
机译:在新开发的轴流室辅助装置(VAD)上进行长期耐久性测试,用流体动力学轴承进行。模拟循环回路由具有机械心阀,储存器,合规罐,电阻阀和由聚合物或钛制成的流动路径的膜片循环环组成。 VAD安装在隔膜泵后面。血液模拟流体是盐水溶液,其在37℃的温度下加入甘油。在一系列流速下将脉动流引入VAD中,以实现给定叶轮旋转的正流量和正压头速度,产生5升/分钟的流速,压力为100mmHg。利用舒张性和收缩流量,分别与0和9.5 / min的舒张性和收缩流率的脉动流动条件分别实现,并且在72bpm的脉冲率下的平均流量与5L / min相似。 VAD操作不仅判断叶轮的转速,而且判断为舒张,收缩和平均流速和VAD的平均压力头。模拟循环回路的条件,包括隔膜泵,流体温度和流体粘度的脉搏率。测试期间有八个VADS 2年来测试,在此期间,它们在运营中不断。 VAD性能因素,包括功耗和振动特性,几乎保持恒定。成功证明了发达的VAD的长期耐久性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号