首页> 外文期刊>Journal of Biomechanics >Contact forces in the tibiofemoral joint from soft tissue tensions: Implications to soft tissue balancing in total knee arthroplasty
【24h】

Contact forces in the tibiofemoral joint from soft tissue tensions: Implications to soft tissue balancing in total knee arthroplasty

机译:来自软组织张力的胫酮型接头中的接触力:对整个膝关节置换术中的软组织平衡的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Proper tension of the knee's soft tissue envelope is important during total knee arthroplasty; incorrect tensioning potentially leads to joint stiffness or instability. The latter remains an important trigger for revision surgery. The use of sensors quantifying the intra-articular loads, allows surgeons to assess the ligament tension at the time of surgery. However, realistic target values are missing. In the framework of this paper, eight non-arthritic cadaveric specimens were tested and the intra-articular loads transferred by the medial and lateral compartment were measured using custom sensor modules. These modules were inserted below the articulating surfaces of the proximal tibia, with the specimens mounted on a test setup that mimics surgical conditions. For both compartments, the highest loads are observed in full extension. While creating knee flexion by lifting the femur and flexing the hip, mean values (standard deviation) of 114 N (71 N) and 63 N (28 N) are observed at 0 flexion for the medial and lateral compartment respectively. Upon flexion, both medial and lateral loads decrease with mean values at 90 degrees flexion of 30 N (22 N) and 6 N (5 N) respectively. The majority of the load is transmitted through the medial compartment. These observations are linked to the deformation of the medial and lateral collaterals, in addition to the anatomy of the passive soft tissues surrounding the knee. In conclusion, these findings provide tangible clinical guidance in assessing the soft tissue loads when dealing with anatomically designed total knee implants. (C) 2017 Elsevier Ltd. All rights reserved.
机译:膝盖的软组织包络的适当张力在整个膝盖关节造身术期间都很重要;不正确的张紧可能导致关节刚度或不稳定性。后者仍然是修订手术的重要触发。使用量化的传感器量化内部载荷,允许外科医生在手术时评估韧带张力。但是,缺少现实的目标值。在本文的框架中,使用定制传感器模块测量八个非关节炎尸体标本,并使用内侧和横向隔室传递的关节内载荷。这些模块插入到近端胫骨的铰接表面下方,标本安装在模拟手术条件的测试设置上。对于两个隔间,在全扩展中观察到最高负载。通过提升股骨并弯曲髋关节并弯曲髋部,分别观察到114 n(71n)和63n(28n)的平均值(标准偏差)分别观察到内侧和横向隔室的0屈曲。在屈曲时,中间和横向载荷的平均值分别以30n(22 n)和6n(5n)的90度屈曲的平均值降低。大部分负载通过内侧隔室传输。除了膝盖周围的被动软组织的解剖学之外,这些观察结果与内侧和侧侧侧侧侧侧的变形相关联。总之,这些研究结果提供了在处理解剖学设计的总膝关节植入物时评估软组织负荷的有形临床指导。 (c)2017 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号