Comparison of NOCSAE head kinematics using the Hybrid III and EuroSID-2 necks

机译:Nocsae Head运动学使用Hybrid III和Eurosid-2颈部的比较

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Anthropomorphic test devices (ATDs) are designed for specific loading scenarios and possess uniquely designed individual components including the neck. The purpose of this study was to determine the influence of the neck surrogate on head kinematics. Inertial loads were generated using a pendulum system with an anthropomorphic head attached to a Hybrid III (HIII) or EuroSID-2 (ES-2) neck. The ATD head-neck assemblies were tested under extension, flexion, lateral bending, oblique extension, and oblique flexion at 3.4?m/s. Peak head kinematics were found to be statistically different with the ES-2 versus HIII neck under certain cases. For extension, the resultant peak linear acceleration (PLA) and resultant peak angular acceleration (PAA) were statistically higher with the ES-2 versus HIII neck. For flexion and lateral bending, there were no statistical differences in the resultant PLA based on neck selection although the resultant PAA was statistically higher with the ES-2 versus HIII neck. For oblique extension, the resultant PLA and PAA statistically increased with the ES-2 versus HIII neck. Furthermore, the acceleration components ax, αx, and αywere statistically higher with the ES-2 neck while ayshowed no statistical difference due to neck selection. For oblique flexion, the resultant PLA and PAA were statistically higher with the ES-2 versus HIII neck. Additionally, the acceleration components ax, ay, αx, and αywere statistically higher with the ES-2 versus HIII neck. These findings indicate that for certain loading directions and acceleration components, head kinematics were influenced by the neck surrogate used.
机译:拟方针测试装置(ATDS)设计用于具体的负载方案,并且具有独特设计的独特组件,包括颈部。本研究的目的是确定颈部替代品对头动脉的影响。使用具有附着在杂合III(HIII)或EUROSID-2(ES-2)颈部的拟蒽型头部产生惯性载荷。在3.4m / s的延伸,屈曲,横向弯曲,倾斜,倾斜延伸和倾斜屈曲下测试ATD头颈组件。在某些情况下,发现峰值动力学与ES-2对HIII颈部有统计不同。对于延伸,所得到的峰值线性加速度(PLA)和得到的峰角加速度(PAA)与ES-2与HIII颈部有统计学上更高。对于屈曲和横向弯曲,基于颈部选择的结果PLA没有统计差异,尽管所得PAA与ES-2与HIII颈部有统计学上更高。对于倾斜延伸,所得PLA和PAA与ES-2与HIII颈部有统计学上增加。此外,随着ES-2颈部的同时,加速分量AX,αx和αywere与ES-2颈部的统计学上更高,而由于颈部选择,无统计学差异无统计差异。对于倾斜屈曲,通过ES-2对HiII颈部具有统计学上更高的PLA和PAA。另外,随着ES-2与HIII颈部,加速分量AX,AY,αx和αywere统计上更高。这些发现表明,对于某些装载方向和加速度组分,头部运动学受到颈部替代的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号