Transferability and within- and between-laboratory reproducibilities of EpiSensA for predicting skin sensitization potential in vitro: A ring study in three laboratories

机译:在体外预测皮肤致敏潜力的复制性和实验室和之间的实验室繁殖能力:三个实验室中的戒指研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The epidermal sensitization assay (EpiSensA) is an in vitro skin sensitization test method based on gene expression of four markers related to the induction of skin sensitization; the assay uses commercially available reconstructed human epidermis. EpiSensA has exhibited an accuracy of 90% for 72 chemicals, including lipophilic chemicals and pre?/pro-haptens, when compared with the results of the murine local lymph node assay. In this work, a ring study was performed by one lead and two naive laboratories to evaluate the transferability, as well as within- and between-laboratory reproducibilities, of EpiSensA. Three non-coded chemicals (two lipophilic sensitizers and one non-sensitizer) were tested for the assessment of transferability and 10 coded chemicals (seven sensitizers and three non-sensitizers, including four lipophilic chemicals) were tested for the assessment of reproducibility. In the transferability phase, the non-coded chemicals (two sensitizers and one non-sensitizer) were correctly classified at the two naive laboratories, indicating that the EpiSensA protocol was transferred successfully. For the within-laboratory reproducibility, the data generated with three coded chemicals tested in three independent experiments in each laboratory gave consistent predictions within laboratories. For the between-laboratory reproducibility, 9 of the 10 coded chemicals tested once in each laboratory provided consistent predictions among the three laboratories. These results suggested that EpiSensA has good transferability, as well as within- and between-laboratory reproducibility. Copyright ? 2018 John Wiley & Sons, Ltd.
机译:表皮敏化测定(episensa)是一种基于与诱导皮肤致敏的基因表达的体外皮肤致敏试验方法;该测定用途使用商业上可用的重建人表皮。 episensa表现出72种化学物质的精度为90%,包括亲脂化学物质和预先α/ pro-Haptens,与鼠局部淋巴结测定结果相比。在这项工作中,一项戒指研究由一个领先的一个领导和两个天真的实验室进行,以评估episensa的可转移性,以及在实验室之间的重复性。测试三种非编码化学品(两种亲脂性敏化剂和一个非敏化剂)进行可转移性评估,并测试10种编码化学品(7种敏化剂和三种非敏化剂,包括四种亲脂性化学物质)以评估再现性。在可转移相位中,未编码化学品(两个敏化剂和一个非敏化剂)在两个幼稚实验室正确分类,表明episensa方案成功转移。对于实验室内的再现性,在每个实验室的三个独立实验中测试的三种编码化学品产生的数据在实验室内进行了一致的预测。对于实验室再现性,在每个实验室中测试的10种编码化学品中的9种提供了一致的三个实验室的一致预测。这些结果表明,episensa具有良好的可转移性,以及在实验室重复性内部和之间的内部和之间。版权? 2018 John Wiley&Sons,Ltd。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号