...
首页> 外文期刊>Journal of AOAC International >Comparison of Assigned Values from Participants' Results, Spiked Concentrations of Test Samples, and Isotope Dilution Mass Spectrometric Results in Proficiency Testing for Pesticide Residue Analysis
【24h】

Comparison of Assigned Values from Participants' Results, Spiked Concentrations of Test Samples, and Isotope Dilution Mass Spectrometric Results in Proficiency Testing for Pesticide Residue Analysis

机译:从参与者的结果,尖刺浓度的试样和同位素稀释质谱结果的比较导致农药残留分析的能力测试

获取原文
获取原文并翻译 | 示例

摘要

The Hatano Research Institute (HRI) at the Food and Drug Safety Center has recently organized a series of proficiency-testing (PT) programs called the "External Quality Control for Food Hygiene" in order to evaluate the analytical capability of testing laboratories that inspect food samples in accordance with the Food Sanitation Act. In one of these programs, Pesticide I, consensus values calculated from the participants' analytical results were used as assigned values, and the spiked concentrations of the prepared test samples were used for evaluating variation among individual participants. In the present study, the values obtained in the 2013-2015 rounds have been assessed by comparing the analytical results of the target pesticides obtained by using two different isotope-dilution MS (IDMS) methods. These two IDMS methods are based on a combination of different pretreatment protocols and different GC separation columns. The weighted means of the observed analytical results were higher than the corresponding assigned values, but showed good agreement with the spiked concentrations. These results indicate that the spiking concentrations of the test sample from HRI are reliable, and therefore, these values can be used to evaluate the trueness of the participants' analytical method.
机译:食品和药物安全中心的Hatano研究所(HRI)最近组织了一系列良好的能力测试(PT)计划,称为“食品卫生外部质量控制”,以评估检测食品的测试实验室的分析能力按照食品卫生法案的样品。在这些程序之一中,农药I,从参与者分析结果计算的共识值用作分配的值,并且制备的测试样品的尖刺浓度用于评估个体参与者之间的变化。在本研究中,通过比较通过使用两种不同的同位素稀释MS(IDMS)方法获得的靶农药的分析结果来评估2013-2015轮中获得的值。这两个IDMS方法基于不同预处理协议和不同GC分离列的组合。观察到的分析结果的加权手段高于相应的分配值,但与尖刺浓度吻合良好。这些结果表明,来自HRI的试验样品的尖峰浓度是可靠的,因此,这些值可用于评估参与者分析方法的特殊性。

著录项

  • 来源
    《Journal of AOAC International》 |2018年第4期|共6页
  • 作者单位

    NMIJ Natl Inst Adv Ind Sci &

    Technol AIST AIST Tsukuba Cent 3 1-1-1 Umezono Tsukuba Ibaraki 3058563 Japan;

    NMIJ Natl Inst Adv Ind Sci &

    Technol AIST AIST Tsukuba Cent 3 1-1-1 Umezono Tsukuba Ibaraki 3058563 Japan;

    NMIJ Natl Inst Adv Ind Sci &

    Technol AIST AIST Tsukuba Cent 3 1-1-1 Umezono Tsukuba Ibaraki 3058563 Japan;

    FDSC HRI 729-5 Ochiai Kanagawa 2578523 Japan;

    FDSC HRI 729-5 Ochiai Kanagawa 2578523 Japan;

    FDSC HRI 729-5 Ochiai Kanagawa 2578523 Japan;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 分析化学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号