New calibration equations are proposed based on the use of intensity ratios of spectral lines and peaks of coherently and incoherently scattered characteristic radiation of an X-ray tube. Prospects for their application to the X-ray fluorescence analysis of samples containing undetectable light elements are shown. The proposed method ensures high precision of determination and performance of analysis in the lack of adequate reference samples. The method was tested on an example of analysis of standard samples of bronze and samples of iron oxide materials.
机译:基于使用光谱线和X射线管的相干散射特性辐射的强度比的强度比和峰的峰值的使用,提出了新的校准方程。 示出了施加到含有未可检测的光元件的样品的X射线荧光分析的前景。 该方法确保了缺乏足够的参考样品的测定和分析性能的高精度。 该方法是在分析青铜和氧化铁材料样品的标准样品的实例上进行测试的。