首页> 外文期刊>Drug research >Determination of JW5473 in Rat Plasma by UPLC-MS/MS and its Application to Pharmacokinetic Study of JW5473
【24h】

Determination of JW5473 in Rat Plasma by UPLC-MS/MS and its Application to Pharmacokinetic Study of JW5473

机译:UPLC-MS / MS测定大鼠等离子体中的JW5473及其在JW5473的药代动力学研究中的应用

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A sensitive method for quantitation of JW5473 in rat plasma has been established using ultra performance liquid chromatography-electrospray ionization tandem mass spectrometry (UPLC-ESI/MS/MS). Tramadol was used as an internal standard. JW5473 and internal standard in plasma sample was extracted using acetonitrile (protein precipitation). A centrifuged upper layer was then evaporated and reconstituted with the mobile phase of 0.5% formic acid-acetonitrile (40:60, v/v). The reconstituted samples were injected into a C_(18) reversed-phase column. Using MS/MS in the multiple reaction monitoring (MRM) mode, JW5473 and tramadol were detected without severe interference from rat plasma matrix. JW5473 produced a protonated precursor ion ([M+H]~(+)) at m/z 432.3 and a corresponding product ion at m/z 114.4. And the internal standard produced a protonated precursor ion ([M+H]~(+)) at m/z 264.4 and a corresponding product ion at m/z 58.1. Detection of JW5473 in human plasma by the UPLC-ESI/MS/MS method was accurate and precise with a quantitation limit of 1.0?ng/mL. The validation, reproducibility, stability, and recovery of the method were evaluated. The method has been successfully applied to pharmacokinetic studies of JW5473 in rat plasma. Pharmacokinetic parameters of JW5473 was evaluated after intravenous (i.?v.; at doses of 15?mg/kg) and oral (p.o.; at doses of 30?mg/kg) administration of JW5473 in rats. After p.o. administration (30?mg/kg) of JW5473, F (Fraction absorbed) value was approximately 70.5%.
机译:使用超高效液相色谱 - 电喷雾电离串联质谱(UPLC-ESI / MS / MS)建立了大鼠等离子体中JW5473的敏感方法。曲马多用作内标。使用乙腈(蛋白质沉淀)提取JW5473和血浆样品中的内标。然后将离心的上层蒸发并重构0.5%甲酸 - 乙腈(40:60,V / V)的流动阶段。将重构样品注入C_(18)反相柱中。在多反应监测(MRM)模式中使用MS / MS,检测到JW5473和曲马多,而不是来自大鼠等离子体基质的严重干扰。 JW5473在M / Z 432.3的M / Z 432.3的质子化前体离子([M + H]〜(+))和M / Z 114.4的相应产物离子。并且内标在M / Z 264.4处产生质子化前体离子([M + H]〜(+))和M / Z 58.1的相应产物离子。通过UPLC-ESI / MS / MS方法检测人血浆中的JW5473是准确的,精确的定量限为1.0≤ng/ ml。评估了该方法的验证,再现性,稳定性和恢复。该方法已成功应用于大鼠血浆JW5473的药代动力学研究。在静脉内(I.O.OW.21.2,1)评价JW5473的药代动力学参数(I.OW.OV.;以15×mg / kg)和口服(p.o。;剂量为30×mg / kg)施用大鼠JW5473。 P.O.施用(30?Mg / kg)JW5473,F(馏分被吸收)值约为70.5%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号