A comparative evaluation of cone beam CT and micro-CT on trabecular bone structures in the human mandible.

机译:锥梁CT和微型CT对人颌骨颌骨结构上的比较评价。

获取原文
获取原文并翻译 | 示例

摘要

The main purpose of this study was to determine the accuracy of cone beam CT (CBCT) in measuring the trabecular bone microstructure, in comparison with micro-CT. The subobjective was to examine to what extent bone quality assessment is influenced by X-ray tube current and voltage settings as well as soft tissue surrounding the bone.Eight human mandibular bone samples were scanned using three different clinical exposure protocol within water (W1-3) and without water (NW1-3) by a high-resolution (80 μm) CBCT machine (3D Accuitomo 170(?); Morita, Kyoto, Japan). Subsequently, the samples underwent micro-CT scanning (SkyScan 1174?; SkyScan, Antwerp, Belgium). After image acquisition, similar volumes of interest of the trabecular structures captured with CBCT and micro-CT were aligned with each other. Segmentation was then performed, and the morphometric parameters were quantified within the volumes of interest by CTAn software (CTAnalyser(?); SkyScan, Antwerp, Belgium). Descriptive statistical analyses and multiple comparisons between all protocols were applied in R software.High positive Pearson's correlation coefficients were observed between CBCT and micro-CT protocols for all tested morphometric indices except for trabecular thickness. No significant differences were observed between all exposure protocols except for trabecular separation. When examining the soft-tissue effect on trabecular bone structures, no significant differences between NW (1-3) and W (1-3) protocols were observed for all variables.The present study demonstrated the potential of high-resolution CBCT imaging for in vivo applications of quantitative bone morphometry and bone quality assessment. However, the overestimation of morphometric parameters and acquisition settings in CBCT must be taken into account.
机译:该研究的主要目的是确定锥形光束CT(CBCT)测量小梁骨微观结构的准确性,与Micro-CT相比。子目标是检查骨质质量评估的程度,骨质质量评估受X射线管电流和电压设置以及骨骼周围的软组织。使用3种不同的临床暴露方案扫描了人的下颌骨样品(W1-3 )通过高分辨率(80μm)CBCT机器(3D Accuitomo 170(?); Morita,京都,日本),没有水(NW1-3)。随后,样品接受了微型CT扫描(Skyscan 1174?; Skyscan,安特卫普,比利时)。在图像采集之后,用CBCT和微CT捕获的小梁结构的类似体积与CBCT和Micro-CT彼此对准。然后进行分割,并在CTAN软件(CtanAlyser(?); Skyscan,安特卫普,比利时)内量化的情况下量化参数。在R软件中应用了所有协议之间的描述性统计分析和多种比较。在除了小梁厚度之外,在CBCT和Micro-CT协议之间观察到的CBCT和微型CT协议之间的相关系数。除了小梁分离外,所有接触方案之间没有观察到显着差异。当检查对小梁骨结构的软组织作用时,对所有变量观察到NW(1-3)和W(1-3)和W(1-3)方案之间没有显着差异。本研究表明了高分辨率CBCT成像的潜力体内应用定量骨形态学和骨质质量评估。但是,必须考虑在CBCT中的形态测量参数和采集设置的高估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号