...
首页> 外文期刊>Trends in Ecology & Evolution >Correlation of Non-invasive Tear Break-Up Time with Tear Osmolarity and Other Invasive Tear Function Tests
【24h】

Correlation of Non-invasive Tear Break-Up Time with Tear Osmolarity and Other Invasive Tear Function Tests

机译:撕裂渗透渗透和其他侵入撕裂功能测试的非侵入式撕裂分段时间的相关性

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Aim: To compare the outcomes of non-invasive break-up time (NI-BUT) test and the other conventional dry eye tests. Methods: The right eyes of 170 subjects were included in the study. In order to evaluate the tear quality of the patients, NI-BUT levels were measured by the Scheimplug-Placido disk system (Sirius topography). Tear osmolarity test was performed with TearLab Osmolarity System. Topical anesthesia-assisted type I Schirmer test and topical anesthesia-assisted BUT were lastly applied to all patients in order not to affect other measurements. Results: The mean NI-BUT value was 9.59 +/- 4.37 sec, tear osmolarity was 292.93 +/- 9.30 mOsm/L, Schirmer test was 15.32 +/- 6.05 mm/5 min, and biomicroscopic BUT value was 8.98 +/- 3.79 sec. The Schirmer test results were statistically significantly correlated with biomicroscopic BUT and NI-BUT values (p = .019, r = 0.180 and p = .030, r = 0.166; respectively). It was also found that tear osmolarity was strongly and inversely correlated with biomicroscopic BUT and topographic NI-BUT values (p < .001, r = -0.554 and p < .001, r = -0.528; respectively). There was no significant correlation between Schirmer test and tear osmolarity. Conclusion: It is important to use a sensitive, reproducible and non-invasive method in the evaluation of tear functions. We think that the objective and noninvasive topographic NI-BUT measurements and the minimally invasive osmolarity measurements should be used more frequently in practice because they are correlated with the measurements obtained by invasive methods and should be widespread in clinics.
机译:目的:比较非侵入性分解时间(Ni-ant)试验的结果和其他常规的干眼症测试。方法:在研究中包含170个受试者的右眼。为了评估患者的撕裂质量,通过Scheimplug-Placido盘系统(Sirius Teopography)测量Ni-Only的水平。用泪草渗透压系统进行泪滴渗透压试验。局部麻醉辅助I型Schirmer测试和局部麻醉辅助,但最后应用于所有患者,以免影响其他测量。结果:平均值为9.59 +/- 4.37秒,泪液渗透量为292.93 +/- 9.30 mosm / l,奇氏测试为15.32 +/- 6.05 mm / 5 min,生物镜,但值为8.98 +/- 3.79秒。 Schirmer试验结果与生物显微镜下而具有统计学显着相关,但Ni-ant值(p = .019,r = 0.180和p = .030,r = 0.166;分别)。还发现泪液渗透压强烈,与生物振视和地形Ni-an,但是值(p <.001,r = -0.554和p <.001,r = -0.528;席氏松测试与泪滴渗透性无明显相关性。结论:在评估撕裂功能时使用敏感,可重复和非侵入性方法是重要的。我们认为客观和非侵入性地形Ni-且测量和微创渗透测量应更频繁地使用,因为它们与通过侵入性方法获得的测量结果相关,并且应该在诊所普及。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号