OBJECTIVE: The objective of our study was to evaluate the detection rate of central airway stent complications using MDCT as compared with bronchoscopy. MATERIALS AND METHODS: A review was performed of all consecutive patients undergoing MDCT and bronchoscopy for suspected complications of airway stents during an 18-month period. MDCT images were interpreted in a blinded fashion by an experienced thoracic radiologist before bronchoscopy was performed, and the accuracy of MDCT was determined using bronchoscopy as the gold standard. MDCT images were specifically assessed for the presence of the following complications: narrowing of stent lumen due to granulation tissue or secretions (or both), stent fracture, stent invasion by adjacent neoplasm, stent migration, and perforation of adjacent airways. RESULTS: The study population was composed of 21 patients, with mean age of 48 years (range, 16-79 years), who underwent tracheal (n = 3), tracheobronchial (n = 7), or bronchial (n = 11) stent placement for benign (n = 13) or malignant (n = 8) airway disorders. Eleven of 21 stents were metallic and the remaining 10 were silicone. Thirty complications were detected in 21 patients, including stent luminal narrowing due to granulation tissue or secretions (or both) (n = 13), stent migration (n = 9), stent fracture (n = 4), stent invasion by adjacent neoplasm (n = 3), and tracheal perforation (n = 1). MDCT accurately detected 29 (97%) of the 30 complications diagnosed by bronchoscopy. There was one false-negative case in which MDCT failed to detect a stent fracture. There were no false-positive diagnoses of stent complications. CONCLUSION: MDCT is highly accurate for detecting airway stent complications.
机译:目的:本研究的目的是评估与支气管镜检查相比,使用MDCT对中央气道支架并发症的检出率。材料与方法:对所有连续18个月接受MDCT和支气管镜检查的患者进行了回顾,评估其气道支架的可疑并发症。在进行支气管镜检查之前,由经验丰富的胸腔放射科医生以盲法对MDCT图像进行解释,并使用支气管镜检查作为金标准来确定MDCT的准确性。专门评估了MDCT图像是否存在以下并发症:由于肉芽组织或分泌物(或两者)引起的支架内腔狭窄,支架断裂,相邻肿瘤侵入支架,支架迁移以及相邻气道穿孔。结果:该研究人群由21例患者组成,平均年龄为48岁(范围16-79岁),他们接受了气管(n = 3),气管支气管(n = 7)或支气管(n = 11)支架的治疗放置良性(n = 13)或恶性(n = 8)气道疾病。 21个支架中有11个是金属支架,其余10个是硅树脂。在21例患者中发现了30例并发症,包括由于肉芽组织或分泌物(或两者)导致的支架腔狭窄(n = 13),支架迁移(n = 9),支架骨折(n = 4),支架被邻近肿瘤侵犯( n = 3)和气管穿孔(n = 1)。在通过支气管镜检查诊断出的30种并发症中,MDCT能够准确检测出29种(97%)。在一例假阴性病例中,MDCT无法检测到支架断裂。没有支架并发症的假阳性诊断。结论:MDCT对气道支架并发症的检测具有很高的准确性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号