首页> 外文期刊>Heart and Lung: The Journal of Critical Care >Lung deposition and systemic bioavailability of different aerosol devices with and without humidification in mechanically ventilated patients
【24h】

Lung deposition and systemic bioavailability of different aerosol devices with and without humidification in mechanically ventilated patients

机译:不同气溶胶装置的肺沉积和系统生物利用性,在机械通风患者中没有加湿

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Abstract Background During mechanical ventilation medical aerosol delivery has been reported to be upto two fold greater with dry inhaled gas than with heated humidity. Urine levels at 0.5?h post dose (URSAL0.5%) has been confirmed as an index of lung deposition and 24?h (URSAL24%) as index of systemic absorption. Our aim was to determine the effect of humidification and aerosol device type on drug delivery to ventilated patients using urine levels. Methods In a randomized crossover design, 36 (18female) mechanically ventilated patients were assigned to one of three groups. Groups 1 and 2 received 5000?μg salbutamol using vibrating mesh (VM) and jet nebulizers (JN), respectively, while group 3 received 1600?μg (16 puffs) of salbutamol via metered dose inhaler with AeroChamber Vent (MDI-AV). All devices were placed in the inspiratory limb of ventilator downstream from the humidifier. Each subject received aerosol with and without humidity at >24?h intervals with >12?h washout periods between salbutamol doses. Patients voided urine 15?min before each study dose and urine samples were collected at 0.5?h post dosing and pooled for the next 24?h. Results The MDI-AV and VM resulted in a higher percentage of urinary salbutamol levels compared to the JN (p? Conclusions Our findings suggest that in-vitro reports overestimate the impact of dry vs. heated humidified conditions on the delivery of aerosol during invasive mechanical ventilation.
机译:据报道,机械通风期间的抽象背景据报道,用热量的湿度,干吸入气体均据报道高达两倍。尿液水平为0.5μm,urmode剂量(URSAL0.5%)已被证实为肺沉积指数,24μm(URSAL24%)作为全身吸收指数。我们的目的是确定加湿和气溶胶装置类型对使用尿液水平的通风患者的药物递送的影响。在随机交叉设计中的方法,36(18Female)机械通风患者被分配给三组中的一个。使用振动网(VM)和喷射雾化器(JN)的组1和2接收5000?μgsalbutamol,而第3组通过使用Aerochamber通风口(MDI-AV)的计量剂量吸入器接收1600μg(16μg)的沙丁胺醇。将所有器件放在加湿器下游的呼吸机的吸气肢体中。每个受试者接受气溶胶,无湿度>24Ω·H间隔,在Salbutamol剂量之间具有> 12?H清洗期。在每次研究剂量和尿液样品中收集在0.5Ω术后,尿液中排出尿液15≤min。结果MDI-AV和VM导致与JN相比较长百分比的尿Salbutamol水平(P?结论我们的研究结果表明,在体外报告中估计干燥与侵袭性机械期间气溶胶加热的湿化条件的影响。通风。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号