...
首页> 外文期刊>Haemophilia: the official journal of the World Federation of Hemophilia >Effects of pre‐analytical heat treatment in factor VIII (FVIII) inhibitor assays on FVIII antibody levels
【24h】

Effects of pre‐analytical heat treatment in factor VIII (FVIII) inhibitor assays on FVIII antibody levels

机译:vIII(FVIIII)抑制剂测定对FVIII抗体水平的反对分析热处理的影响

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Introduction The use of pre‐analytical heat treatment ( PHT ) with the Nijmegen‐Bethesda assay ( NBA ) for inhibitors to factor VIII ( FVIII ) can remove/destroy infused or endogenous FVIII from patient plasma samples, allowing testing of recently infused patients with haemophilia. Two PHT methods have been described as follows: heating to 56°C for 30?minutes and heating to 58°C for 90?minutes. Data examining the effects of PHT on anti‐ FVIII IgG 4 , the antibodies known to correlate most closely with the presence of FVIII inhibitors, are limited. Aim To assess the effect of PHT on the levels of detectable anti‐ FVIII IgG 4 . Methods Nijmegen‐Bethesda assay‐positive specimens were incubated at 56, 58 or 60°C for 90?minutes, and anti‐ FVIII IgG 4 was measured by fluorescence immunoassay ( FLI ) at 30‐minute intervals. The effects of PHT on the ability of recombinant FVIII ( rFVIII ) to inhibit detection of patient antibodies by FLI was also examined to assess the stability of rFVIII under the various PHT conditions tested. Results Levels of anti‐ FVIII IgG 4 showed little change following incubations at 56°C (mean 101% of original value at 30?minutes and 100% at 60?minutes) but decreased upon exposure to 58°C (mean 85% at 30?minutes and 66% at 60?minutes). In addition, heating to 56°C effectively decreased the ability of rFVIII to block antibody binding compared to unheated rFVIII . Conclusion The optimal temperature for PHT in the FVIII NBA is 56°C. Higher temperatures may lead to loss of inhibitory antibodies.
机译:引入使用前分析热处理(PHT)与奈米氏 - 贝乙醚测定(NBA)用于因子VIII(FVIII)的抑制剂(FVIII),可以从患者血浆样品中去除/破坏注入或内源性FVIII,从而允许测试最近注入的血友病患者。已经描述了两种PHT方法:加热至56℃,30.分钟,加热至58℃以进行90?分钟。检查PHT对抗FVIII IgG 4的影响的数据,已知与FVIII抑制剂的存在最密切相关的抗体受限。目的评估PHT对可检测抗FVIII IgG 4水平的影响。方法将Nijmegen-Bethesda测定阳性标本在56,58或60℃下孵育90.℃,并通过30分钟的荧光免疫测定(FLI)测量抗FVIII IgG 4。还研究了PHT对重组FVIII(RFVIII)能力抑制患者抗体的能力的影响,以评估测试的各种PHT条件下RFVIII的稳定性。结果抗FVIII IgG 4的水平显示在56℃下孵育后的几乎没有变化(平均101%在30?分钟,在60?分钟时为100%),但在暴露于58℃时(平均为85% ?分钟和66%在60?分钟)。此外,与未加热的RFVIII相比,加热至56℃,有效地降低了RFVIII阻断抗体结合的能力。结论FVIII NBA中PHT的最佳温度为56℃。较高的温度可能导致抑制抗体的丧失。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号