首页> 外文期刊>AJNR. American journal of neuroradiology >Reproducibility, interrater agreement, and age-related changes of fractional anisotropy measures at 3T in healthy subjects: effect of the applied b-value.
【24h】

Reproducibility, interrater agreement, and age-related changes of fractional anisotropy measures at 3T in healthy subjects: effect of the applied b-value.

机译:健康受试者在3T时的重现性,间质一致性和与年龄相关的分数各向异性测量值变化:b值的影响。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

BACKGROUND AND PURPOSE: There is no reproducibility study of fractional anisotropy (FA) measurements at 3T using regions of interest (ROIs). Our purpose was to establish the extent and statistical significance of the interrater variability, the variability observed with 2 different b-values, and in 2 separate scanning sessions. MATERIALS AND METHODS: Twelve healthy volunteers underwent MR imaging twice. MR imaging was performed on a 3T unit, and FA maps were analyzed independently by 2 observers using ROIs positioned in the corpus callosum, internal capsules, corticospinal tracts, and right thalamus. Changes in FA values (x10(3)) measured with 2 b-values (700 and 1000 s/mm(2)), age-related differences, interobserver agreement, and measurement reproducibility were assessed. RESULTS: In the right internal capsule genu (FA = 702/728; b = 1000/700 s/mm(2)) and the left anterior limb of the internal capsule (AIC; FA = 617/745; b 1000/700 s/mm(2)), the FA values were significantly different between the 2 b-values (P = .02 and .05, respectively). Significant age-related differences in FA were observed in the genu of the corpus callosum and in the left AIC. Interrater measurements showed fair-to-moderate agreement for most anatomic structures. The lowest significant change for a single subject regarding any FA values between the 2 sessions was in the corpus callosum (4%), whereas the highest one was in the corticospinal tracts (27%). The Bland-Altman plot analysis showed that the 1000-s/mm(2) b-value gave satisfactorily reproducible measurements equally good or better than the 700-s/mm(2) b-value. CONCLUSION: The reproducibility of FA estimates using ROIs was satisfactory. Measurements with a b-value at 1000 s/mm(2) showed superior reproducibility in most anatomic locations.
机译:背景与目的:目前尚无研究使用感兴趣区域(ROI)在3T测量分数各向异性(FA)的可重复性。我们的目的是确定间质变异性的程度和统计意义,该变异性是在2个不同的b值以及2个单独的扫描会话中观察到的。材料与方法:12名健康志愿者接受了两次MR成像。在3T装置上进行MR成像,并由两名观察员使用位于2体,内囊,皮质脊髓束和右丘脑中的ROI独立分析FA图。评估了用2个b值(700和1000 s / mm(2))测量的FA值(x10(3))的变化,与年龄有关的差异,观察者之间的一致性以及测量的可重复性。结果:在右内囊(gen = 702/728; b = 1000/700 s / mm(2))和内囊的左前肢(AIC; FA = 617/745; b 1000/700 s / mm(2)),则两个b值之间的FA值显着不同(分别为P = .02和.05)。在call体的属和左AIC中观察到FA的与年龄相关的显着差异。评定者间的测量结果表明,大多数解剖结构的吻合程度中等至中等。对于两个主题之间的任何FA值,单个受试者的最低显着变化是在call体中(4%),而最高的是在皮质脊髓束中(27%)。 Bland-Altman图分析表明,1000-s / mm(2)b值可令人满意地重现测量结果,其质量优于或优于700-s / mm(2)b值。结论:使用ROI进行FA估计的重现性令人满意。 b值为1000 s / mm(2)的测量结果表明,在大多数解剖位置上均具有出色的重现性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号