首页> 外文期刊>The International journal of oral & maxillofacial implants >Implications of Wear at the Titanium-Zirconia Implant-Abutment Interface on the Health of Peri-implant Tissues
【24h】

Implications of Wear at the Titanium-Zirconia Implant-Abutment Interface on the Health of Peri-implant Tissues

机译:钛 - 氧化锆植入界面磨损的影响对Peri植入组织的健康状况

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: To investigate the presence of metallic particles in the peri-implant mucosa around titanium dental implants after 5 years of loading using single-implant crowns with respect to clinical signs of peri-implant inflammation. Materials and Methods: Sixteen participants from an ongoing, prospective, single-arm clinical trial who had received titanium dental implants restored with single maxillary crowns veneered to zirconia abutments were available for the study. Exfoliative cytology samples were obtained from the peri-implant tissues and contralateral tooth sites using microbrushes and were evaluated by means of light microscopy (LM), scanning electron microscopy, and energy-dispersive spectroscopy (EDS). Trace elemental analysis was also carried out on the microbrushes using inductively coupled plasma mass spectrometry. Peri-implant and periodontal parameters (plaque, bleeding, attachment level, radiographic bone levels) were recorded. Results: Titanium particles were found in both the single-implant crown and contralateral natural tooth sites. LM and EDS analyses showed significantly higher numbers of Ti particles at the implant-abutment interfaces (mean = 14.168; SD = 2.36) and in the internal aspects of peri-implant mucosa in contact with the prostheses (mean = 4.438; SD = 2.22) when compared with other test and control areas. Mean probing depths were = 3 mm, and no differences were found in plaque or bleeding on probing between implant and tooth sites. Median bone levels were within the normal range for both implant (mesial: 0.5 mm; distal: 0.8 mm) and tooth (mesial: 1.5 mm; distal: 1.8 mm) sites. Conclusion: Loading of single-implant zirconia crowns can cause the release of Ti particles because of functional wear at the implant-abutment level. The presence of these metal particles in the peri-implant area did not appear to affect peri-implant health in this patient group.
机译:目的:在使用单植入冠的临床症状的临床症状后5年后探讨钛牙科植入物周围的钛牙科植入物周围的金属颗粒的存在。材料和方法:从正在进行的,前瞻性的单手臂临床试验中获得恢复单个上颌牙冠的持续,前瞻性的单臂临床试验的16名参与者可用于该研究。使用微动脉刷从PER-植入组织和对侧齿部位获得脱抗性细胞学样本,并通过光学显微镜(LM),扫描电子显微镜和能量分散光谱(EDS)评价。还使用电感耦合等离子体质谱法在微生物中进行痕量元素分析。记录围植入物和牙周参数(牙菌斑,出血,附着水平,放射线骨水平)。结果:钛颗粒在单植入冠和对侧天然齿部位中发现。 LM和EDS分析在植入邻接界面处显示出大量的Ti颗粒(平均值= 14.168; sd = 2.36)和与假体接触的Peri植入粘膜的内部方面(平均值= 4.438; sd = 2.22)与其他测试和控制区域相比。平均探测深度= 3mm,在植入物和牙齿位点之间的探测中没有发现斑块或出血。中位骨水平在植入物(间隙:0.5mm;远端:0.8 mm)和牙齿(间隙:1.5mm;远端:1.8mm)位点的正常范围内。结论:单胞注射氧化锆冠的装载可能导致由于植入级水平的功能磨损而导致Ti颗粒的释放。在该患者组中,围植入区域中这些金属颗粒的存在并未影响Peri-植入物健康。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号