首页> 外文期刊>AJNR. American journal of neuroradiology >Preliminary results of the luna aneurysm embolization system in a rabbit model: a new intrasaccular aneurysm occlusion device.
【24h】

Preliminary results of the luna aneurysm embolization system in a rabbit model: a new intrasaccular aneurysm occlusion device.

机译:兔模型中月球动脉瘤栓塞系统的初步结果:一种新型的囊内动脉瘤闭塞装置。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND AND PURPOSE: Recent advances in endovascular devices have been aimed at providing high density, mesh-like metallic materials across the aneurysm neck, in place of coil technology. Therefore our aim was to report the in vivo preclinical performance of a self-expanding intrasaccular embolization device. MATERIALS AND METHODS: Elastase-induced aneurysms were created in 12 rabbits. Each aneurysm was embolized with a Luna AES. DSA was performed preimplantation; 5, 10, and 30 minutes postimplantation; and at 1 month in 12 rabbits and at 3 months in 8 rabbits. Early postimplantation intra-aneurysmal flow was graded as unchanged, moderately diminished, or completely absent. One- and 3-month DSAs were graded by using a 3-point scale (complete, near-complete, or incomplete occlusion). Aneurysms were harvested for gross and microscopic histologic evaluation at 1 month (n = 4) and at 3 months (n = 8). Tissues within the aneurysm dome and across the aneurysm neck were assessed by using HE staining. RESULTS: Ten (83%) of 12 aneurysms demonstrated complete cessation of flow within 30 minutes of device implantation. At 1-month follow-up, 10 (83%) of 12 aneurysms were completely occluded. At 3 months, 7 of 8 (88%) aneurysms remained completely occluded. One-month gross examination in 4 rabbits demonstrated that membranous tissue completely covered the device in 3 subjects (75%). Microscopic examination showed that 3 aneurysms had loose connective tissue filling the aneurysm cavity. Three-month gross and microscopic examinations demonstrated membranous tissue completely covering the device, loose connective tissue filling the aneurysm cavity, and neointima formation crossing the aneurysm neck in 8 of 8 (100.0%) subjects. CONCLUSIONS: The Luna AES achieved high rates of complete angiographic occlusion and showed promising histologic findings in the rabbit aneurysm model.
机译:背景和目的:血管内装置的最新进展旨在代替线圈技术而在动脉瘤颈上提供高密度的网状金属材料。因此,我们的目的是报告一种自膨胀囊内栓塞装置的体内临床前性能。材料与方法:在12只兔子中产生了由弹性蛋白酶诱导的动脉瘤。每个动脉瘤均用Luna AES栓塞。 DSA在植入前进行;植入后5、10和30分钟; 12只兔子在1个月时和8只兔子在3个月时。植入后早期的动脉瘤内血流被定为未改变,适度减少或完全消失。使用3分制(完全,接近完全或不完全咬合)对1个月和3个月DSA进行分级。在第1个月(n = 4)和第3个月(n = 8)收获动脉瘤进行肉眼和显微镜下的组织学评估。通过使用HE染色评估动脉瘤穹顶内和整个动脉瘤颈部的组织。结果:12个动脉瘤中有10个(83%)在装置植入后30分钟内显示完全停止血流。在1个月的随访中,12个动脉瘤中有10个(83%)被完全阻塞。在3个月时,8个动脉瘤中有7个(88%)仍被完全阻塞。在4只兔子中进行了为期一个月的大体检查,结果表明3名受试者(75%)的膜组织完全覆盖了该装置。显微镜检查显示3个动脉瘤有疏松的结缔组织充满动脉瘤腔。为期三个月的肉眼和显微镜检查显示,在8名(100.0%)受试者中,有8名(100.0%)的膜组织完全覆盖了该装置,松散的结缔组织充满了动脉瘤腔,并且新内膜形成穿过动脉瘤的颈部。结论:Luna AES在兔动脉瘤模型中实现了较高的完全血管造影闭塞率,并显示出令人鼓舞的组织学发现。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号