首页> 外文期刊>AJNR. American journal of neuroradiology >Variable porosity of the pipeline embolization device in straight and curved vessels: A guide for optimal deployment strategy
【24h】

Variable porosity of the pipeline embolization device in straight and curved vessels: A guide for optimal deployment strategy

机译:直管和弯管中管道栓塞装置的可变孔隙率:最佳部署策略指南

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND AND PURPOSE: Low-porosity endoluminal devices for the treatment of intracranial aneurysms, also known as flow diverters, have been in experimental and clinical use for close to 10 years. Despite rigorous evidence of their safety and efficacy in well-controlled trials, a number of key factors concerning their use remain poorly defined. Among these, none has received more attention to date than the debate on how many devices are optimally required to achieve a safe, effective, and economical outcome. Additional, related questions concern device sizing relative to the parent artery and optimal method of deployment of the devices. While some or all of these issues may be ultimately answered on an empiric basis via subgroup analysis of growing treatment cohorts, we believe that careful in vitro examination of relevant device properties can also help guide its in vivo use. MATERIALS AND METHODS: We conducted a number of benchtop experiments to investigate the varied porosity of Pipeline Embolization Devices deployed in a simulated range of parent vessel diameters and applied these results toward conceptualizing optimal treatment strategies of fusiform and wide-neck aneurysms. RESULTS: The results of our studies confirm a predictable parabolic variability in device porosity based on the respective comparative sizes of the device and recipient artery, as well as device curvature. Even modest oversizing leads to a significant increase in porosity. CONCLUSIONS: The experiments demonstrate various deleterious effects of device oversizing relative to the parent artery and provide strategies for addressing size mismatches when they are unavoidable.
机译:背景和目的:用于治疗颅内动脉瘤的低孔隙度腔内装置,也被称为分流器,已经在实验和临床上使用了将近10年。尽管有严格的证据证明它们在安全对照试验中的安全性和有效性,但与使用它们有关的许多关键因素仍不清楚。在这些方法中,到目前为止,没有比最需要多少个设备才能达到安全,有效和经济结果的辩论更受关注了。另外的相关问题涉及相对于亲代动脉的装置尺寸和装置的最佳部署方法。尽管可以通过对不断增长的治疗人群进行亚组分析最终在经验基础上回答其中的部分或全部问题,但我们认为,对相关器械特性进行仔细的体外检查也有助于指导其体内使用。材料与方法:我们进行了许多台式实验,以研究在模拟的母血管直径范围内部署的管道栓塞装置的不同孔隙率,并将这些结果用于概念化梭形和宽颈动脉瘤的最佳治疗策略。结果:我们的研究结果证实了装置孔隙率的可预测抛物线变化,这是基于装置和受体动脉的各自比较尺寸以及装置曲率得出的。即使适度的过大尺寸也会导致孔隙率显着增加。结论:实验证明了装置尺寸过大相对于亲代动脉的各种有害作用,并提供了在不可避免的情况下解决尺寸不匹配的策略。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信