首页> 外文期刊>Thrombosis and Haemostasis: Journal of the International Society on Thrombosis and Haemostasis >Enhanced Thrombolysis by Ultrasound-Assisted Catheter-Directed Thrombolysis and Microbubbles in an In Vitro Model of Iliofemoral Deep Vein Thrombosis
【24h】

Enhanced Thrombolysis by Ultrasound-Assisted Catheter-Directed Thrombolysis and Microbubbles in an In Vitro Model of Iliofemoral Deep Vein Thrombosis

机译:通过超声辅助导管导向的导管溶栓和微泡来增强溶栓和微泡的Ilioforal深静脉血栓形成的体外模型

获取原文
获取原文并翻译 | 示例
       

摘要

There is a need to improve the efficacy and safety of catheter-directed thrombolysis (CDT) for thrombo-occlusive diseases, and ultrasound-assisted CDT (USAT) is a promising approach. We tested if thrombolysis efficacy of USAT can be improved by adding gaseous microbubbles (MB). We developed an in vitro dynamic overflow model for iliofemoral deep vein thrombosis, and added MB to an USAT system with ultrasound energy and dose of tissue plasminogen activator according to clinical practice. A total of 64 clots (mean baseline weight of 8.231.12g, generated from citrated human whole blood from 7 healthy male volunteers) were randomly assigned to 1 of 4 study protocols of 30 minutes' duration: negative control, CDT, USAT, and USAT+MB. Thrombolysis efficacy was assessed by measuring the change in D-dimer levels in the overflow liquid and the percentage of clot weight reduction. Compared to negative control, change in D-dimer increased by 62% (p =0.017), 128% (p=0.002), and 177% (p<0.001) in the CDT, USAT, and USAT+MB groups, respectively. D-dimer increase was greater in the USAT than in the CDT group (p=0.014), and greater in the USAT+MB than in the USAT group (p=0.033). Compared to negative control, percentage of clot weight reduction increased by 123% (p=0.016), 154% (p=0.002), and 233% (p<0.001) in the CDT, USAT, and USAT+MB groups, respectively. Percentage of clot weight reduction was greatest in the USAT+MB group (p<0.05 compared with all other groups). In conclusion, our in vitro study suggests that the thrombolytic efficacy of USAT in human whole blood clots can be improved by local administration of MB.
机译:需要提高导管导向溶栓(CDT)对血栓闭塞疾病的疗效和安全性,而超声辅助的CDT(USAT)是一种有前途的方法。我们通过添加气体微泡(MB)来改善USAT的溶栓疗效等。我们开发了一种用于Ilioforal Deep Vein血栓形成的体外动态溢流模型,并根据临床实践,将MB与超声能量和组织纤溶酶原激活剂的超声能量和剂量的usat系统。总共64个凝块(平均基线重量为8.231.12g,从7个健康的男性志愿者那里由柠檬酸的人全血生成)被随机分配给4个研究方案的1个30分钟持续时间:阴性对照,CDT,USAT和USAT + MB。通过测量溢流液中的D-二聚体水平的变化和凝块重量的百分比来评估溶栓疗效。与阴性对照相比,D-二聚体的变化分别增加了62%(p = 0.017),128%(p = 0.002)和CDT,USAT和USAT + MB组的177%(P <0.001)。除了CDT组中,D-二聚体升高比CDT组(P = 0.014)较大,比USAT组更大,而不是USAT组(P = 0.033)。与阴性对照相比,CDT,USAT和ASAT + MB组中,凝块重量减少的百分比增加123%(p = 0.016),154%(p = 0.002),和233%(P <0.001)。 USAT + MB组中凝块重量的百分比最大(与所有其他组相比,P <0.05)。总之,我们的体外研究表明,通过局部施用MB,可以改善USAT在人体整体血栓中的溶栓疗效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号