首页> 外文期刊>The Journal of arthroplasty >Outcomes of Newer Generation Cementless Total Knee Arthroplasty: Beaded Periapatite-Coated vs Highly Porous Titanium-Coated Implants
【24h】

Outcomes of Newer Generation Cementless Total Knee Arthroplasty: Beaded Periapatite-Coated vs Highly Porous Titanium-Coated Implants

机译:较新一代无粘合性膝盖关节术的结果:串珠脱衣矿涂层VS高度多孔钛涂层植入物

获取原文
获取原文并翻译 | 示例
           

摘要

Background: Newer generation cementless total knee arthroplasty (TKA) designs are available and have novel implant coatings. We evaluated and compared beaded periapatite (PA)-coated vs highly porous titanium-coated cementless TKAs. Specifically, we compared: (1) survivorship, (2) Knee Society Scores (KSSs) and range of motion, (3) complications, and (4) radiographic findings.
机译:背景:较新一代软泥全膝关节置换术(TKA)设计可供选择,并具有新的植入涂层。 我们评估和比较了串珠的Periapatite(PA) - 涂料VS高度多孔钛涂覆的粘合剂。 具体而言,我们比较:(1)生存,(2)膝关节社会评分(KSSS)和运动范围,(3)并发症和(4)射线显影结果。