首页> 外文期刊>Orthopedics >Radiographic Calibration With a Prosthetic Femoral Head Allows Accurate Preoperative Templating for Total Hip Arthroplasty
【24h】

Radiographic Calibration With a Prosthetic Femoral Head Allows Accurate Preoperative Templating for Total Hip Arthroplasty

机译:带有假体股头的射线照相校准允许精确的术前模板用于总髋关节置换术

获取原文
获取原文并翻译 | 示例
           

摘要

Templating for total hip arthroplasty requires proper radiographic calibration. One option for radiograph calibration is using a cobalt-chrome femoral head ball. The authors reviewed radiographs and clinical data for patients undergoing primary total hip arthroplasty. Radiographs were calibrated using a 28-mm cobalt-chrome femoral head ball. Agreements between templated and actual implant size were calculated. The templated acetabulum matched within one size of the actual acetabulum in 76.7% to 80.0% of cases. The templated femur matched within one size of the actual femur in 83.3% to 93.3% of cases. This technique is an attractive option when a standardized calibration marker is unavailable.
机译:总髋关节置换术的模板需要适当的射线照相校准。 X线校准的一种选择是使用钴铬股头球。 作者介绍了接受初级髋关节置换术患者的射线照片和临床数据。 使用28毫米钴 - 铬股头球校准射线照相。 计算模板和实际植入大小之间的协议。 模板包弓形曲线姆在实际髋臼的一个尺寸内匹配,76.7%至80.0%的病例。 模板化股骨在一个尺寸的实际股骨内匹配,83.3%至93.3%的病例。 当标准化校准标记不可用时,该技术是一种吸引人的选择。