Objectives The arthroscopic "lateral gutter drive-through" (LGDT) sign is reported to diagnose popliteus tendon (PT) injury with high sensitivity and specificity. However, no study has provided a postoperative evaluation of combined posterior cruciate ligament (PCL) and posterolateral corner (PLC) injuries using the LGDT test. Methods From January 2012 to January 2015, a total of 80 consecutive patients who underwent combined PCL reconstruction and PLC surgeries were identified. Fifty eligible patients were included in this study for evaluation with subjective scoring systems, physical examinations, posterior and varus stress radiographs, and second-look arthroscopic surgeries during hardware removal operation. Results Forty-nine patients were available for a mean of 31.5 +/- 9.3 months follow-up (range, 24.0-81.0 months). In terms of PLC injury pattern, there were 27 type A, 10 type B, and 12 type C patients, with 21 acute cases and 28 chronic cases. At the final follow-up, subjective scores were all significantly improved. The side-to-side difference (SSD) of posterior tibial translation (PTT) improved from 18.4 +/- 9.2 mm (range, 12.9-25.6 mm) to 5.2 +/- 5.0 mm (range, -5.0-18.5 mm, P < 0.001), and the SSD of tibial external rotation by dial test (ER) decreased from 18.0 degrees +/- 14.4 degrees (range, 13.0 degrees-22.0 degrees) to 1.2 degrees +/- 7.5 degrees (range, -9.0 degrees-22.0 degrees, P < 0.001). In patients with type C injury, the SSD of the lateral opening decreased from 14.2 +/- 6.6 mm (range, 22-10.2 mm) to 0.9 +/- 3.1 mm (range, -4.4-6 mm, P < 0.001). In a comparison between patients with positive and negative LGDT signs, the LGDT-negative patients had significant superiority in subjective scores, SSD of PTT, and SSD of ER. The sensitivity and specificity of the LGDT test in detecting postoperative posterolateral rotational instability (PLRI) were calculated as 100% and 88.4%, respectively. Conclusions In the series of surgically treated patients with PCL and PLC injury: (i) patients had improved subjective and objective clinical outcome after combined PCL reconstruction and PLC surgery at a minimum of 24-months follow-up; and (ii) second arthroscopic LGDT sign testing had high sensitivity and specificity in detecting postoperative PLRI, and a positive LGDT sign was related with inferior subjective and objective results.
机译:据报道,目标关节镜“横向沟渠驱动”(LGDT)标志以高灵敏度和特异性诊断Popliteus肌腱(Pt)损伤。然而,没有使用LGDT试验提供了使用LGDT测试的组合后十字花韧带(PCL)和后侧角(PLC)损伤的术后评价。方法从2012年1月到2015年1月,确定了80名接受PCL重建和PLC手术的连续80名患者。本研究涉及五十个符合条件的患者,用于评估主观评分系统,体检,后验和杂音射线照片,以及在硬件去除操作期间的二看关节镜手术。结果49例患者的平均值为31.5 +/- 9.3个月(范围,24.0-81.0个月)。在PLC损伤模式方面,有27型A,10型B和12型C患者,21例急性病例和28例慢性病例。在最后的后续行动中,主观评分都得到了显着改善。后胫骨平移(PTT)的侧向侧差(SSD)从18.4 +/- 9.2毫米(范围,12.9-25.6毫米)至5.2 +/- 5.0 mm(范围,-5.0-18.5mm,p <0.001),曲线外旋转的SSD通过拨号测试(ER)从18.0度+/- 14.4度(范围,13.0度-22.0度)降低到1.2度+/- 7.5度(范围,-9.0度 - 22.0度,p <0.001)。在C型损伤患者中,横向开口的SSD从14.2 +/- 6.6mm(范围,22-10.2mm)降至0.9 +/- 3.1mm(范围,-4.4-6mm,p <0.001)。在阳性和阴性LGDT标志患者之间的比较中,LGDT阴性患者在主观评分,PTT的SSD和ER的SSD具有显着优越性。 LGDT试验在检测术后后外侧旋转不稳定(PLRI)的敏感性和特异性分别计算为100%和88.4%。结论在患有PCL和PLC损伤的手术治疗患者的系列中:(i)患者在最低24个月后组合PCL重建和PLC手术后提高了主观和客观临床结果; (ii)第二关节镜LGDT标志测试在检测术后PLRI方面具有很高的敏感性和特异性,并且阳性LGDT标志与较差的主观和目标结果有关。

著录项

  • 来源
    《Orthopaedic surgery》 |2019年第3期|共9页
  • 作者单位

    Beijing Jishuitan Hosp Sports Med Serv 31 Xinjiekou East St Beijing 100035 Peoples R China;

    Beijing Jishuitan Hosp Sports Med Serv 31 Xinjiekou East St Beijing 100035 Peoples R China;

    Beijing Jishuitan Hosp Sports Med Serv 31 Xinjiekou East St Beijing 100035 Peoples R China;

    Beijing Jishuitan Hosp Sports Med Serv 31 Xinjiekou East St Beijing 100035 Peoples R China;

    Beijing Jishuitan Hosp Sports Med Serv 31 Xinjiekou East St Beijing 100035 Peoples R China;

    Beijing Jishuitan Hosp Sports Med Serv 31 Xinjiekou East St Beijing 100035 Peoples R China;

    Beijing Jishuitan Hosp Sports Med Serv 31 Xinjiekou East St Beijing 100035 Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 外科学;
  • 关键词

    Lateral gutter drive through test; Popliteal tendon; Posterior cruciate ligament reconstruction; Posterolateral corner;

    机译:横向排水沟通过试验;popliteal肌腱;后十字韧带重建;后侧角;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号