首页> 外文期刊>Orthodontics & craniofacial research >Accuracy and reliability of digital craniofacial measurements using a small‐format, handheld 3D camera
【24h】

Accuracy and reliability of digital craniofacial measurements using a small‐format, handheld 3D camera

机译:使用小型格式,手持3D相机进行数字颅面测量的准确性和可靠性

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Structured Abstract Objectives Craniofacial assessments often involve three‐dimensional facial imaging using an expensive camera with 6 SLR lenses to analyse the positions and relations of anatomic landmarks. Recently, a 3D small‐format, handheld camera was developed; however, the accuracy and reliability of this system are largely unknown. The purpose of this study was to evaluate the accuracy and reliability of this system. Materials & Methods A total of 30 sets of evaluations were completed by 2 examiners on 5 human subjects, using 3 different methods: direct callipers, 3D handheld camera and conventional tripod 3D camera images. Each evaluation included 29 anthropometric landmarks that were used as reference points for facial analysis. Two examiners marked the landmarks directly on the faces and measured linear distances using the 3 measurement methods. Results Accuracy analysis was performed for handheld vs direct calliper vs conventional camera measurements. Each of these analyses yielded a grand mean of correlation coefficients of .98. Bias measurements revealed that the handheld and conventional camera methods yielded larger measurements than direct callipers (with a mean difference of 1.74, 1.56?mm, respectively, for rater 1 and 0.94, 1.02?mm, respectively, for rater 2). When compared to one another, both the handheld camera and the conventional camera methods yielded similar values for most measurements, with the average overall difference between these modalities of 0.03?mm for rater 1 and 0.07?mm for rater 2. Conclusions The 3D handheld camera showed high accuracy and reliability in comparison with traditional models, indicating that this system may provide a useful tool in craniofacial anthropometry.
机译:结构化的摘要目标颅面评估通常涉及使用昂贵的相机涉及三维面部成像,其中6个单反镜头分析解剖标志的位置和关系。最近,开发了3D小型手持式相机;但是,该系统的准确性和可靠性在很大程度上是未知的。本研究的目的是评估该系统的准确性和可靠性。材料&方法使用3种人受试者,共有30套评估,使用3种不同的方法,使用3种不同的方法完成:直接卡尺,3D手持式相机和传统三脚架3D相机图像。每个评估包括29个人的人类测量标志,用作面部分析的参考点。两位审查员用3个测量方法直接标记在面上并测量线性距离。结果对手持式VS直接Calliper进行了准确性分析VS常规相机测量。这些分析中的每一个都产生了.98的相关系数的宏观平均值。偏置测量表明,手持式和传统的相机方法产生的测量比直接呼叫者(分别为1.74,1.56Ωmm,分别为Rater 1和0.94,102Ωmm,分别为1.74,1.02Ω·mm)。当彼此相比,手持式相机和传统的相机方法都产生了类似的数量测量值,这些模式之间的这些模式之间的平均总差为0.03Ωmm的额为1和0.07Ωmm的额定值2.结论3D手持式相机与传统模型相比,表明该系统可以提供高精度和可靠性,表明该系统可以在颅面上提供有用的工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号