The study provides the overall results of the national individual monitoring service in Gabon obtained during the 2018 International Atomic Energy Agency Africa region intercomparison exercise on measurements of the personal dose equivalent H-p(10) in photon fields. The dosimetry system tested was the microStar InLight dosimetry system (Landauer, Inc., USA). The results were assessed using the trumpet curve. Requirements for photon energy, linearity, coefficient of variation and mixed irradiations were also assessed against IEC 62387 standard. The reader stability, zero dose, recording levels and the ability of the dosemeter to act as a crude energy spectrometer for low energy photons were evaluated as well. The results for reader stability were in line with the manufacturer' specifications, and the photomultiplier tube count measurements relative to the dark current and the built-in C-14 radioactive source passed the chi-square test proposed. Monthly and quarterly recording level and zero dose values were calculated to be 0.057 +/- 0.003 mSv, 0.05 +/- 0.01 mSv and 0.110 +/- 0.001 mSv, respectively. The overall results obtained during the 2018 intercomparison exercise met the requirement for overall accuracy (trumpet curve). For the dose equivalent, photon radiation energy and angle of incidence ranges tested, the results for coefficient of variation, energy dependence and mixed irradiations met the corresponding IEC 62387 standard requirements. The results for linearity were considered satisfactory with respect to the corresponding IEC 62387 standard requirement. The method proposed to estimate workplace low photon energies provided better results than the system algorithm. This study has demonstrated that the national individual monitoring service can provide a reliable and consistent accurate dosimetry service to its customers.
机译:该研究提供了2018年国际原子能机构非洲地区互相熟练在2018年国际原子能机构中获得的加蓬全国个人监测服务的总体结果对光子田的个人剂量等效H-P(10)的测量。测试的剂量测定系统是MicroStar Inlight Dosimetry系统(Landauer,Inc.,USA)。使用小号曲线评估结果。还评估了光子能量,线性度,变异系数和混合辐照的要求。还评价了读者稳定性,零剂量,记录水平和称为低能量光子的粗能谱仪的能力。读者稳定性的结果符合制造商的规格,以及相对于暗电流的光电倍增管计数测量和内置的C-14放射源通过了所提出的Chi-Square测试。每月和季度记录水平和零剂量值分别计算为0.057 +/- 0.003msV,0.05 +/- 0.01msV和0.110 +/- 0.001msV。 2018年依普利型练习期间获得的总体结果符合总体准确性(小号曲线)的要求。对于剂量等同物,测试的光子辐射能量和发生的入射角度,变异系数,能量依赖性和混合照射的结果达到了相应的IEC 62387标准要求。对于相应的IEC 62387标准要求,线性度的结果被认为是令人满意的。提出估计工作场所低光子能量的方法提供了比系统算法更好的结果。本研究表明,全国个人监测服务可以为其客户提供可靠和一致的准确剂量服务。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号