摘要

In patient-specifically instrumented (PSI) total knee arthroplasty, the correlation between the pre-operative surgical plan, accuracy of the cutting block, and intra-operative resection size is unclear. The aim of this study was to evaluate the ability to accurately execute the PSI surgical plan and to add to the merging information with respect to this technology with the hypothesis that the PSI blocks would demonstrate good accuracy with regard to the bony thickness of the resections.
机译:在患者专门仪表(PSI)总膝关节置换术中,术前手术计划,切割块的准确性和手术间切除尺寸之间的相关性尚不清楚。 本研究的目的是评估准确执行PSI外科手术计划的能力,并在该技术中加入合并信息,其中假设PSI块在切除杆的骨骼厚度方面表现出良好的准确性。