A method to calibrate a force transducer under dynamic conditions has been developed. Calibration is achieved by a drop ball test based on the levitation mass method using an optical interferometer. From the conducted experiments, the output of the force transducer could be corrected, in line with the previous paper written by the authors. Moreover, the dynamic correction coefficient could be obtained by this method, even without an expensive air slider, which was used in our previous method. The calibration performed by the developed method proved to be very significant in correcting the dynamic force measurement error by the force transducer with a very small root mean square (RMS) error compared to the results of measurement in the absence of calibration and dynamic correction. The RMS error of measurement result by the force transducer with dynamic calibration and dynamic correction using the developed method is about 1.6N. This error is equivalent to 1% of the maximum force applied to the force transducer, which is approximately 160N.
机译:已经开发了一种在动态条件下校准力换能器的方法。基于使用光学干涉仪的悬浮质量法实现校准。根据所进行的实验,可以依次纠正力传感器的输出,符合作者写的前一篇文章。此外,即使没有昂贵的空气滑块,可以通过在我们之前的方法中使用的昂贵的空气滑块来获得动态校正系数。通过在没有校准和动态校正的测量结果的情况下,由开发方法执行的由开发方法执行的校准在校正具有非常小的根均线(RMS)误差的力换能器的动态力测量误差非常显着。使用开发方法具有动态校准和动态校正的力换能器的测量结果的RMS误差为约1.6N。该误差相当于施加到力换能器的最大力的1%,其约为160n。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号