首页> 外文期刊>Mikrochimica Acta: An International Journal for Physical and Chemical Methods of Analysis >A glassy carbon electrode modified with nitrogen-doped reduced graphene oxide and melamine for ultra-sensitive voltammetric determination of bisphenol A
【24h】

A glassy carbon electrode modified with nitrogen-doped reduced graphene oxide and melamine for ultra-sensitive voltammetric determination of bisphenol A

机译:用氮气掺杂的石墨烯氧化物和三聚氰胺改性玻璃碳电极,用于超敏伏安法测定双酚A.

获取原文
获取原文并翻译 | 示例
       

摘要

A composite was prepared at room temperature from nitrogen-doped reduced graphene oxide (N-rGO) and melamine via -interaction. An ultra-sensitive electrochemical sensor for the determination of trace levels of bisphenol A (BPA) was obtained by coating a glassy carbon electrode (GCE) with the composite. The structure and morphology of composite were characterized by FTIR, Raman, XRD, XPS, SEM and TEM. Because of the synergetic effects of N-rGO and melamine, the modified GCE displays considerably enhanced sensitivity to BPA. The voltammetric response, typically measured at a peak of 0.48V (vs. SCE) is linear in the 0.05 to 20M BPA concentration range, and the detection limit is 0.8nM (at S/N=3). The sensor is reproducible, stable and selective. It was applied to analyze baby bottles, drinking cups, mineral water bottles and shopping receipts that were spiked with BPA, and the recoveries reached 99.1-101.4%.
机译:在室温下从氮气掺杂的氧化石墨烯(N-RGO)和三聚氰胺通过 - 互动制备复合材料。 通过用复合材料涂覆玻璃状碳电极(GCE),获得用于测定痕量的双酚A(BPA)的超敏电化学传感器。 复合材料的结构和形态特征在于FTIR,拉曼,XRD,XPS,SEM和TEM。 由于N-RGO和三聚氰胺的协同作用,改性的GCE显示出对BPA的显着增强的敏感性。 通常在0.48V(Vs.Sce)的峰值下测量的伏安响应是在0.05至20m的BPA浓度范围内线性,并且检测限为0.8nm(在S / N = 3)。 传感器可再现,稳定和选择性。 它适用于分析婴儿瓶,饮用杯,矿泉水瓶和掺入BPA的购物收据,回收率达到99.1-101.4%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号