首页> 外文期刊>Food analytical methods >Determination of Sulphiting Agents in Raw and Processed Meat: Comparison Between a Modified Monier-Williams Method and the Direct Analysis by Ion Chromatography with Conductometric Detection
【24h】

Determination of Sulphiting Agents in Raw and Processed Meat: Comparison Between a Modified Monier-Williams Method and the Direct Analysis by Ion Chromatography with Conductometric Detection

机译:原料加工肉中硫化剂的测定:改性型号的莫尔威素方法与电导检测离子色谱直接分析的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Sulphiting agents are a class of compounds that are used as preservatives since they release SO2 in food. Regarding meat products, the legislation restricts the use of these food additives, due to some toxic effects that they may have in humans. The most employed analytical procedure for the determination of sulphiting agents in foodstuffs is the Monier-Williams (M-W) method, but the reliability of this method was called into question by several authors. In this work, the M-W method was modified by replacing both the distillation unit to shorten the extraction time (from hours to 5 min) and the final titration with a chromatographic separation followed by conductometric detection of sulphate ion (m-M-W/IC-CD). This method was then validated, and the performance parameters were compared with those of the method based on the direct analysis of sulphite ion by ion chromatography with conductometric detection (DIC-CD). Linearity, accuracy at 40 and 80 mg kg(-1) of SO2 and measurement uncertainty resulted comparable. Accuracy at 10 mg kg(-1) of SO2 resulted higher for the m-M-W/IC-CD method, but this parameter could be influenced by traces of other sulphur-containing compounds that may be present in meat. The limit of determination of the m-M-W/IC-CD method was slightly higher than that obtained by the DIC-CD method. Finally, through spiking tests, it was proved that sulphide, 2-methyl-3-furanthiol and l-methionine cause "false-positive" responses, by using M-W-based methods.
机译:硫化剂是一类用作防腐剂的化合物,因为它们在食物中释放SO2。关于肉类产品,立法限制了这些食品添加剂的使用,因为它们可能在人类中可能具有一些毒性效果。用于测定食品中硫化剂的最常用的分析程序是莫尔威廉姆斯(M-W)方法,但是该方法的可靠性被几个作者调用了问题。在这项工作中,通过更换蒸馏单元来改变M-W方法以将提取时间(从小时至5分钟从2小时从小时到5分钟)和最终滴定,然后通过色谱分离,然后进行硫酸根(M-M-W / IC-CD)进行传导检测。然后验证了该方法,并将性能参数与基于亚硫酸根离子的直接分析与电导检测(DIC-CD)进行比较。线性,40和80mg kg(-1)的精度和测量不确定度导致可比。对于M-M-W / IC-CD法导致10mg kg(-1)的精度导致M-M-W / IC-CD方法更高,但该参数可能受到含有肉中可能存在的其他含硫化合物的痕量的影响。 M-W / IC-CD法测定的极限略高于DIC-CD法得到的限制。最后,通过尖刺试验,通过使用基于M-W基方法,证明硫化硫化物,2-甲基-3-Furanthiol和L-蛋氨酸导致“假阳性”反应。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号