首页> 外文期刊>Graefe's archive for clinical and experimental ophthalmology: Albrecht von Graefes Archiv fur klinische und experimentelle Opthalmologie >Small incision lenticule extraction (SMILE) lenticule thickness readout compared to change in axial length measurements with the IOLMaster
【24h】

Small incision lenticule extraction (SMILE) lenticule thickness readout compared to change in axial length measurements with the IOLMaster

机译:小切口晶格提取(微笑)晶格厚度读数与IOLMASTER轴向长度测量的变化相比

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose To compare theoretical values from the small incision lenticule extraction (SMILE) lenticule thickness readout with change in axial length measurements taken with the IOLMaster. Methods We prospectively studied 214 eyes from 107 patients undergoing bilateral SMILE surgery for myopia or myopic astigmatism between December 2014 and May 2017 at an ophthalmological practice in Singapore. All eyes were examined pre-operatively and 1 and 3 months post-operatively with the IOLMaster following SMILE surgery. Achieved lenticule thickness was taken as the change in axial length after surgery. A linear mixed-effects model was used to examine changes in axial length, spherical equivalent and acuity over time. The relationships between change in axial length and theoretical lenticule thickness and spherical equivalent were examined with multiple linear regression analyses, and model prediction was assessed with adjusted R-2 statistics. Results Mean (95% confidence interval [CI]) spherical equivalent pre-operatively was - 5.25 (95% CI - 5.38 to - 5.12) diopters (D), at 1 month was 0.04 (95% CI - 0.09 to 0.17) D (p < 0.001), and at 3 months was - 0.02 (95% CI - 0.15 to 0.11) D (p < 0.001). Mean (95% CI) pre-operative axial length was 27,726 (95% CI 25,595 to 25,857) mu m. Post-operative axial length at 1 month was significantly shorter at 25,595 (95% CI 25,464 to 25,726) mu m (p < 0.001) with no change thereafter (p = 0.647). Pre-operative mean +/- standard deviation (SD) refractive target was 0.24 (+/- 0.3) D, and mean difference between target and post-operative spherical equivalent at 1 month was 0.20 D (95% CI 0.16 to 0.25 D, p < 0.001). Multiple regression analysis showed that change in axial length at 1 month was, on average, 5% lower than theoretical lenticule thickness, indicating an average difference of 5.4 mu m (95% CI 5.2 to 5.6 mu m). Preoperative spherical equivalent predicted negative association with change in axial length at 1 month (beta = - 14.8, 95% CI - 18.2 to - 11.3, adjusted R-2 = 0.457, p < 0.001). Conclusions Calculated lenticule thickness values were less than expected, and post-operative refractive outcomes at 1 month showed a slight under-correction. Further research in this area is needed to validate these findings.
机译:目的要比较小切口仔细提取(微笑)晶格厚度读数的理论值,随着Iolmaster拍摄的轴长测量变化。方法从2014年12月至2017年12月间在新加坡的眼科实践中,我们前瞻性地研究了107名接受双侧微笑手术的近视或近视散光患者的214名眼睛。在微笑手术后,所有眼睛都会预先操作性地和1和3个月的术语术后。在手术后逐渐变为轴向长度的变化。线性混合效应模型用于在时间上检查轴向长度,球形等效和敏锐度的变化。用多元线性回归分析检查轴向长度和理论晶格厚度和球面等同物之间的关系,并评估了调整后的R-2统计数据的模型预测。结果平均值(95%置信区间[CI])球形等当量预算 - 5.25(95%CI-5.38至-5.12)屈光度(D),1个月为0.04(95%CI - 0.09至0.17)D( P <0.001),3个月为0.02(95%CI - 0.15至0.11)D(P <0.001)。平均值(95%CI)预次轴向长度为27,726(95%CI 25,595至25,857)mu m。在1个月的术后轴向长度为25,595(95%CI 25,464至25,726)mu m(p <0.001),此后没有变化(p = 0.647)。术前平均值+/-标准偏差(SD)折射靶为0.24(+/- 0.3)D,1个月的靶和术后球形等当量的平均差异为0.20d(95%CI 0.16至0.25 d, p <0.001)。多元回归分析表明,轴向长度在1个月的变化平均为5%,低于理论细粒厚度,表明平均差为5.4μm(95%CI 5.2至5.6μm)。术前球形等效预测的负关联与1个月(β= - 14.8,95%CI-18.2至-11.3的轴长变化,调节R-2 = 0.457,P <0.001)。结论计算的三萜厚度值小于预期,并且1个月的后术后屈光结果显示出轻微的矫正。需要进一步研究该领域以验证这些发现。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号