Design A prospective pilot study. Study population Five orthodontic residents in a university setting were asked to wear Bluetooth-enabled Hawley retainers for 12 hours per day except for eating and brushing. The subjects used an iPod to record the exact times that the retainer was inserted and removed. Data analysis The Bluetooth-enabled device within the Hawley retainer takes a temperature reading every ten minutes. The median difference in retainer wear was reported across a five-day study period, measured in minutes either by the device or self-reported by each subject. As the device only takes a temperature reading every ten minutes, the potential for under-reporting retainer wear was considered using a calculation to adjust for the number of times the retainers were inserted and removed. The median difference between the adjusted and unadjusted wear times were reported. A Wilcoxon matched-pairs signed rank test was used to test clinical accuracy, defined as an overall median margin of error of 5% or less for the device. Results One device malfunctioned and was replaced. Two subjects failed to synchronise their device with their iPod within 24 hours and were reminded to do so by text. The median difference between the self- and device-reported wear times (percent error) was 35 minutes or 5.1 % (range 3.3%-7.5%) using unadjusted data and 13 minutes or 1.9% (range 0.5%-3.4%) using adjusted data.Conclusions The Bluetooth-enabled device showed a clinically acceptable level of accuracy compared to self-reported retainer wear, once the data was adjusted to account for the ten-minute time interval between measurements.
机译:设计前瞻性试验研究。学习人口五大正畸居民在大学环境中被要求佩戴蓝牙的霍利保持者每天12小时,除了吃喝和刷牙。受试者使用iPod记录了插入和移除了固定器的确切次数。数据分析Hawley Retainer内的启用蓝牙设备每十分钟读取温度读数。在五天的研究期间报告了保持器磨损的中位数差异,通过设备或每个受试者自我报告以分钟计量。由于设备仅需十分钟即可读取温度读取,因此使用计算考虑了报告欠的保持器磨损的可能性,以调整插入和移除固定器的次数。报道了调整和不调整的磨损时间之间的中位数差异。使用Wilcoxon匹配对签名的等级测试来测试临床准确性,定义为设备的整体中值误差为5%或更小。结果一个设备发生故障,已被替换。两个受试者未能在24小时内将其设备与其iPod同步,并提醒您通过文本来执行此操作。使用未经调整的数据和13分钟或1.9%(范围为0.5%-3.4%(范围0.5%-3.4%(范围0.5%-3.4%)的自我和设备报告的磨损时间(误差)之间的中位数为35分钟或5.1%(范围3.3%-7.5%)数据组合时支持蓝牙的设备与自我报告的固定器佩戴相比,临床上可接受的准确度,一旦调整数据,以考虑测量之间的十分钟时间间隔。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号