Objectives The diagnostic reading of follow-up low-dose whole-body computed tomography (WBCT) examinations in patients with multiple myeloma (MM) is a demanding process. This study aimed to evaluate the diagnostic accuracy and benefit of a novel software program providing rapid-subtraction maps for bone lesion change detection. Methods Sixty patients (66 years +/- 10 years) receiving 120 WBCT examinations for follow-up evaluation of MM bone disease were identified from our imaging archive. The median follow-up time was 292 days (range 200-641 days). Subtraction maps were calculated from 2-mm CT images using a nonlinear deformation algorithm. Reading time, correctly assessed lesions, and disease classification were compared to a standard reading software program. De novo clinical reading by a senior radiologist served as the reference standard. Statistics included Wilcoxon rank-sum test, Cohen's kappa coefficient, and calculation of sensitivity, specificity, positive/negative predictive value, and accuracy. Results Calculation time for subtraction maps was 84 s +/- 24 s. Both readers reported exams faster using subtraction maps (reader A, 438 s +/- 133 s; reader B, 1049 s +/- 438 s) compared to PACS software (reader A, 534 s +/- 156 s; reader B, 1486 s +/- 587 s; p < 0.01). The course of disease was correctly classified by both methods in all patients. Sensitivity for lesion detection in subtraction maps/conventional reading was 92%/80% for reader A and 88%/76% for reader B. Specificity was 98%/100% for reader A and 95%/96% for reader B. Conclusion A software program for the rapid-subtraction map calculation of follow-up WBCT scans has been successfully tested and seems suited for application in clinical routine. Subtraction maps significantly facilitated reading of WBCTs by reducing reading time and increasing sensitivity.
机译:目的对多种骨髓瘤(MM)患者进行后续低剂量全身计算断层扫描(WBCT)检查的诊断读数是一种苛刻的过程。本研究旨在评估新软件程序的诊断准确性和益处,为骨病变变化检测提供快速减法图。方法从我们的成像档案中鉴定了60例患者(66岁+/- 10年)接受120 WBCT对MM骨病的后续评估检查的检查。中位后续时间为292天(范围为200-641天)。使用非线性变形算法从2MM CT图像计算减法图。将阅读时间,正确评估的病变和疾病分类与标准阅读软件程序进行比较。 De Novo临床阅读高级放射学家作为参考标准。统计包括Wilcoxon Rank-Sum测试,Cohen的Kappa系数,以及计算灵敏度,特异性,正/负预测值,以及准确性。结果减法地图的计算时间为84 s +/- 24 s。两位读者报告使用减法图更快地报告考试(读者A,438 S +/- 133 S;与PACS软件相比(读卡器A,534 S +/- 156 S;读者B, 1486 S +/- 587 S; P <0.01)。所有患者中的两种方法都是正确归类的疾病疗程。减法地图/常规读数中病变检测的敏感性为读卡器A的92%/ 80%,读者B的88%/ 76%,读卡器的特异性为98%/ 100%,读者B的95%/ 96%。结论用于快速减法地图计算的软件程序已成功测试,似乎适用于临床常规的应用。减法图通过减少阅览时间和提高灵敏度,显着促进了WBCT的读数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号