首页> 外文期刊>International Journal of Modern Physics, C. Physics and Computers >Denoising of Raman spectroscopy for biological samples based on empirical mode decomposition
【24h】

Denoising of Raman spectroscopy for biological samples based on empirical mode decomposition

机译:基于经验模型分解的生物样品中拉曼光谱的去噪

获取原文
获取原文并翻译 | 示例
           

摘要

Raman spectroscopy of biological samples presents undesirable noise and fluorescence generated by the biomolecular excitation. The reduction of these types of noise is a fundamental task to obtain the valuable information of the sample under analysis. This paper proposes the application of the empirical mode decomposition (EMD) for noise elimination. EMD is a parameter free and adaptive signal processing method useful for the analysis of nonstationary signals. EMD performance was compared with the commonly used Vancouver algorithm (VRA) through artificial data (Teflon), synthetic (Vitamin E and paracetamol) and biological (Mouse brain and human nails) Raman spectra. The correlation coefficient (rho) was used as performance measure. Results on synthetic data showed a better performance of EMD (rho = 0.52) at high noise levels compared with VRA (rho = 0.19). The methods with simulated fluorescence added to artificial material exhibited a similar shape of fluorescence in both cases (rho = 0.95 for VRA and rho = 0.93 for EMD). For synthetic data, Raman spectra of vitamin E were used and the results showed a good performance comparing both methods (rho = 0.95 for EMD and rho = 0.99 for VRA). Finally, in biological data, EMD and VRA displayed a similar behavior (rho = 0.85 for EMD and rho = 0.96 for VRA), but with the advantage that EMD maintains small amplitude Raman peaks. The results suggest that EMD could be an effective method for denoising biological Raman spectra, EMD is able to retain information and correctly eliminates the fluorescence without parameter tuning.
机译:生物样品的拉曼光谱呈现因生物分子激发产生的不良噪音和荧光。降低这些类型的噪声是获得在分析下获得样品的宝贵信息的基本任务。本文提出了经验模式分解(EMD)对噪声消除的应用。 EMD是一种可用于分析非营出信号的可用和自适应信号处理方法。将EMD性能与常用的温哥华算法(VRA)进行比较,通过人工数据(Teflon),合成(维生素E和乙酰氨基酚)和生物(小鼠脑和人指甲)拉曼光谱。相关系数(RHO)用作性能措施。合成数据的结果显示与VRA(RHO = 0.19)相比,在高噪声水平下表现出更好的EMD(RHO = 0.52)。添加到人造材料中的模拟荧光的方法在两种情况下表现出类似的荧光形状(rho = 0.95,用于rho = 0.93的EMD)。对于合成数据,使用维生素E的拉曼光谱,结果表明,两种方法(rho = 0.95用于vra的rho = 0.99),表现出良好的性能。最后,在生物数据中,EMD和VRA显示了类似的行为(对于EMD和RHO = 0.96的RHO = 0.85,对于VRA),但有的优点是EMD保持小幅度拉曼峰。结果表明,EMD可以是用于去噪的生物拉曼光谱的有效方法,EMD能够保留信息并正确消除没有参数调谐的荧光。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号