An optimal calibration method for a micro-electro-mechanical inertial measurement unit (MIMU) is presented in this paper. The accuracy of the MIMU is highly dependent on calibration to remove the deterministic errors of systematic errors, which also contain random errors. The overlapping Allan variance is applied to characterize the types of random error terms in the measurements. The calibration model includes package misalignment error, sensor-to-sensor misalignment error and bias, and a scale factor is built. The new concept of a calibration method, which includes a calibration scheme and a calibration algorithm, is proposed. The calibration scheme is designed by D-optimal and the calibration algorithm is deduced by a Kalman filter. In addition, the thermal calibration is investigated, as the bias and scale factor varied with temperature. The simulations and real tests verify the effectiveness of the proposed calibration method and show that it is better than the traditional method.
机译:本文提出了一种用于微机械惯性测量单元(MIMU)的最佳校准方法。 MIMU的准确性高度依赖于校准,以消除系统错误的确定性误差,这也包含随机误差。 重叠的Allan方差被应用于在测量中表征随机误差术语的类型。 校准模型包括封装错位误差,传感器到传感器未对准错误和偏置,构建了比例因子。 提出了一种包括校准方案和校准算法的校准方法的新概念。 校准方案由D-OPTEMAL设计设计,并且通过卡尔曼滤波器推断校准算法。 此外,研究了热校准,因为偏置和比例因子随温度而变化。 模拟和实际测试验证了所提出的校准方法的有效性,并表明它比传统方法更好。