...
首页> 外文期刊>Archives of orthopaedic and trauma surgery. >Is the novel olecranon tension plate a valid alternative to tension band wiring of olecranon fractures? A biomechanical study on cadaver bones
【24h】

Is the novel olecranon tension plate a valid alternative to tension band wiring of olecranon fractures? A biomechanical study on cadaver bones

机译:新的Olecranon张力板是冬青骨折的张力带布线的有效替代方案吗? 尸体骨骼的生物力学研究

获取原文
获取原文并翻译 | 示例
           

摘要

Abstract Introduction Tension band wiring (TBW) used for olecranon fractures is afflicted with a high rate of complications. The aim of this study was to compare the stability of the TBW versus an alternative, novel low-profile olecranon tension plate (OTP) with angular stable screws in a simulated complex fracture model. Materials and methods Nine fresh-frozen pairs of cadaver proximal ulnae with an oblique osteotomy and an additional wedge fragment simulating an unstable fracture were tested. The TBW and OTP were implanted pairwise. The elbow motion was simulated in a single-muscle model and ranged from full extension to 90° of flexion. The pulling force of the triceps tendon ranged from 50 to 200?N. The displacement of the fracture fragments was measured with a video motion analysis system over 304 cycles. Data were assessed statistically using the Wilcoxon signed-rank test. Results The cyclic loading tests showed mean loosening of the fracture fragments at the articular surface of 0.56?mm using TBW (SD 0.65) and 0.15?mm for OTP (SD 0.39). There was no statistical significance in loosening between the two constructs ( p ?=?0.31). No plate breakage or screw loosening occurred. Conclusions The low-profile OTP, using the principles of pre-tensioning, lag, cortical, and angular stable screws together, demonstrated similar stability after olecranon fracture fixation when compared with the TBW technique and a lag screw in the olecranon fracture model with a third wedge fragment.
机译:摘要引言用于Olecranon Fractures的张力带布线(TBW)受到高度并发症的折磨。本研究的目的是比较TBW与替代新型低调的奥克兰隆张力板(OTP)的稳定性,在模拟复合骨折模型中具有角度稳定螺钉。用倾斜骨质图和模拟不稳定骨折的额外楔形片段,九对近端溃疡近ulnae近ulnae。 TBW和OTP成对植入。肘部运动在单肌型号中模拟,并从全延伸到90°屈曲。三头肌腱的拉力范围为50至200?n。用超过304个循环的视频运动分析系统测量骨折片段的位移。数据使用Wilcoxon签名等级测试进行统计评估。结果使用TBW(SD 0.65)和OTP(SD 0.39)的TBW(SD 0.65)和0.15Ωmm在0.56Ωmm的关节表面下的循环加载试验显示平均裂缝片段的平均松动。在两个构建体之间松动没有统计学意义(P?= 0.31)。没有发生板块破损或螺杆松动。结论使用预张紧,滞后,皮质和角度稳定螺钉的原理,在冬季骨折技术与第三种中的鹿角骨折模型中的滞后螺钉相比,使用预张紧,滞后,皮质和角度稳定螺钉的原理展示了类似的稳定性。楔形片段。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号