首页> 外文期刊>Acta tropica: Journal of Biomedical Sciences >Evaluation of the performance of CareStart Malaria Pf/Pv Combo rapid diagnostic test for the diagnosis of malaria in Jimma, southwestern Ethiopia.
【24h】

Evaluation of the performance of CareStart Malaria Pf/Pv Combo rapid diagnostic test for the diagnosis of malaria in Jimma, southwestern Ethiopia.

机译:评价CareStart疟疾Pf / Pv组合快速诊断测试在埃塞俄比亚西南部吉马的疟疾诊断中的性能。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

OBJECTIVE: To evaluate the diagnostic performance of CareStart Malaria Pf/Pv Combo test relative to microscopy, for the diagnosis of falciparum and vivax malaria in Ethiopia. METHODS: Two hundred and forty febrile patients visiting the Serbo health center in Jimma zone, southwestern Ethiopia, were involved in this study in 2008. Giemsa-stained thin and thick blood smears were prepared and microscopically examined under a 100x oil immersion microscope objective for Plasmodium species identification and determination of parasitemia respectively. CareStart Malaria Pf/Pv Combo test was performed as per the manufacturers' instruction. FINDINGS: The validity of CareStart Malaria Pf/Pv Combo test for the diagnosis of Plasmodium was very good with a sensitivity of 95.8%, specificity of 100%, positive predictive value of 100% and negative predictive value of 96%. The test performed equally well for the identification of Plasmodium falciparum and P. vivax. The diagnostic performance of this CareStart test is comparable to light microscopy of thin and thick blood smears. CONCLUSION: Although CareStart Malaria Pf/Pv Combo test and blood microscopy have comparable diagnostic performance for Plasmodium detection, the CareStart test has the added advantage of being simple to interpret, cost-efficient, and hence it is preferable to use this rapid diagnostic test for malaria diagnosis in areas where microscopy is not accessible and during times of malaria epidemics that are observed approximately every 4-5 years in Ethiopia.
机译:目的:评价相对于显微镜的CareStart Malaria Pf / Pv Combo试验的诊断性能,用于诊断埃塞俄比亚的恶性疟和间日疟。方法:2008年,在埃塞俄比亚西南部吉马地区的Serbo保健中心就诊的240例发​​热患者参与了该研究。准备了吉姆萨染色的稀薄和厚薄的血涂片,并在100倍油浸显微镜下进行了镜检种类鉴定和寄生虫测定。按照制造商的说明进行了CareStart疟疾Pf / Pv组合测试。结果:CareStart疟疾Pf / Pv Combo检测对疟原虫的诊断非常有效,灵敏度为95.8%,特异性为100%,阳性预测值为100%,阴性预测值为96%。该测试在鉴定恶性疟原虫和间日疟原虫方面同样表现出色。此CareStart测试的诊断性能可与薄和厚血涂片的光学显微镜媲美。结论:尽管CareStart疟疾Pf / Pv组合测试和血液镜检在疟原虫检测方面具有可比的诊断性能,但CareStart测试还具有易于解释,具有成本效益的附加优势,因此,最好将这种快速诊断测试用于在埃塞俄比亚大约每4-5年观察不到显微镜的地区以及疟疾流行期间进行疟疾诊断。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号