首页> 外文期刊>Archives of Environmental Protection >The effect of a Sewage Treatment Plant modernization on changes in the microbiological and physicochemical quality of water in the receiver
【24h】

The effect of a Sewage Treatment Plant modernization on changes in the microbiological and physicochemical quality of water in the receiver

机译:污水处理厂现代化对接收器微生物和物理化学质量的变化的影响

获取原文
获取原文并翻译 | 示例
       

摘要

Due to insufficient operation efficiency, the studied treatment plant has undergone modernization. The aim of this study was to assess whether this modernization improved quality of the STP effluent and water quality in the receiver. The research period of fifty months covered time before and after the modernization. Samples were collected in four sites - upstream and downstream of the STP and by the sewage discharge. Electrolytic conductivity, water temperature and pH were measured onsite. Chemical analyzes were based on ion chromatography and determined the concentration of NH4+,NO3-,NO2-, PO43-, TDS. Microbiological analysis comprised serial dilutions to assess the number of mcsophilic and psychrophilic bacteria and membrane filtration to enumerate E. faecalis, total and fecal conforms as well as total and fecal E. coli. Values of most analyzed parameters did not improve after the modernization, or improved for a very short period of time (NH4+), while some of them even increased, such as PO43-, total and thermotolerant coliforms and E coll. The maximum value of thermotolerant E. coli reached nearly 7 million CFU/100 ml and was observed after modernization. Also at the sites situated downstream of the STP some of analyzed parameters increased. The conducted modernization did not improve the quality of treated sewage and even a further deterioration was observed. It could have been a result of rapidly growing number of tourists visiting the studied area, thus generating large amounts of sewage causing STP overload coupled with poor water and wastewater management. Significant percentage of unregistered tourists hinders proper assessment of the STP target efficiency.
机译:由于操作效率不足,所研究的处理厂经历了现代化。本研究的目的是评估这一现代化是否能够提高STP流出物和接收器水质的质量。在现代化之前和之后的五十个月的研究期限。在四个位置收集样品 - STP的上游和下游和污水排放。在现场测量电解电导率,水温和pH。化学分析基于离子色谱法,并确定NH4 +,NO3,NO2-,PO43-,TDS的浓度。微生物分析包括连续稀释液,以评估麦克白和肌肉细菌和膜过滤的数量,以枚举E.粪便,总和粪便符合总和和粪便大肠杆菌。大多数分析参数的值在现代化之后没有改善,或者改善了很短的时间(NH4 +),而其中一些甚至增加,例如PO43-,总和热调节大肠菌体和E Coll。热调虫大肠杆菌的最大值达到近700万CFU / 100毫升,现代化后观察到。同样在STP下游的位点,一些分析的参数增加。进行的现代化并未提高处理过的污水质量,甚至观察到进一步的恶化。它可能是迅速越来越多的游客访问研究区域,从而产生了大量的污水,导致STP过载加上不良水和废水管理。大量未登记的游客妨碍了对STP目标效率的正确评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号