首页> 外文期刊>Advanced Composites Letters >HEALTH MONITORING OF SINGLE LAP JOINT OF WOVEN GLASS FIBRE REINFORCED EPOXY COMPOSITES MODIFIED WITH MWCNTs
【24h】

HEALTH MONITORING OF SINGLE LAP JOINT OF WOVEN GLASS FIBRE REINFORCED EPOXY COMPOSITES MODIFIED WITH MWCNTs

机译:MWCNTs修饰的玻璃纤维增​​强环氧树脂复合材料单搭接接头的健康监测

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

In this study, in situ monitoring of single lap joint of woven glass fabric reinforced epoxy composites modified with multi-walled carbon nanotubes (MWCNTs) is presented. Woven glass fibre reinforced/epoxy composite plates modified with 3% wt. highly electrically conductive MWCNTs were manufactured by hand lay-up process for obtaining adherends. MWCNTs were used in 1% and 2% by weight in order to investigate the effect of the MWCNTs level on the shear lap joint strength and the self-sensing sensitivity of bonded area. One, four, and seven plies of adhesive woven cloths were employed for bonding adherends to examine the thickness effect on both the shear lap joint strength and the self-sensing sensitivity of bonded area. In order to provide low electrical contact resistance, woven carbon fibres were placed on the top and bottom of the glass fibre layer during production. Results indicate that the health monitoring of lap joints in the woven glass reinforced epoxy composites can be successfully achieved.
机译:在这项研究中,对多壁碳纳米管(MWCNTs)改性玻璃纤维增​​强的环氧复合材料的单搭接接头进行了现场监测。玻璃纤维增​​强/环氧复合板,经3%wt。高导电性的MWCNT是通过手工铺层工艺制造的,以获得被粘物。 MWCNT的使用量为1%和2%(重量),以研究MWCNTs水平对剪切搭接强度和粘合区自感灵敏度的影响。用一层,四层和七层粘合织布粘合被粘物,以研究厚度对剪切搭接强度和粘合区域自感灵敏度的影响。为了提供低的电接触电阻,在生产过程中将编织碳纤维放置在玻璃纤维层的顶部和底部。结果表明,编织玻璃纤维增​​强环氧树脂复合材料搭接接头的健康监测可以成功实现。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号