首页> 外文期刊>Analytical Letters >Electrochemical Determination of Cadmium, Lead, and Nickel Using a Polyphenol-Polyvinyl ChlorideBoron-Doped Diamond Electrode
【24h】

Electrochemical Determination of Cadmium, Lead, and Nickel Using a Polyphenol-Polyvinyl ChlorideBoron-Doped Diamond Electrode

机译:使用多酚聚乙烯氯硼硼掺杂金刚石电极的电化学测定镉,铅和镍

获取原文
获取原文并翻译 | 示例

摘要

Boron-doped diamond electrode surfaces were modified by a polyphenolpolyvinyl chloride membrane. The polyphenols were extracted from the skin of acorns, the fruit of the oak tree. The polymer film was applied on the boron-doped diamond electrode surface by solvent evaporation. The resulting polyphenol-polyvinyl chloride-boron-doped diamond electrode was used as a sensor for cadmium, lead, and nickel. The synergy between the chemically modified surfaces and electrochemical performances of the boron-doped diamond microcell electrode was examined by differential pulse anodic stripping voltammetry at nanomolar concentrations of the three metal ions. The modified electrode provided a stable, sensitive, and selective response to cadmium, lead(II), and nickel(II) ions. The resulting detection limits were 0.0221, 0.25, and 0.00424 nmole L-1, respectively.
机译:通过多酚聚氯乙烯膜改性掺杂的金刚石电极表面。 从橡子皮肤萃取多酚,橡树树的果实。 通过溶剂蒸发将聚合物膜涂布在硼掺杂的金刚石电极表面上。 所得的多酚 - 聚氯乙烯 - 硼掺杂金刚石电极用作镉,铅和镍的传感器。 通过在三个金属离子的纳米摩尔浓度的纳米摩尔浓度下,通过差分脉冲阳极剥离伏安来检查化学改性表面和电化学性能之间的协同作用。 改性电极对镉,铅(II)和镍(II)离子提供稳定,敏感和选择性的反应。 得到的检测限为0.0221,0.25和0.00424米吲哚L-1。