A postcolumn fluorescence reaction system for the high-performance liquid chromatographic (HPLC) determination of tetrodotoxin in the silver-cheeked toadfish Lagocephalus sceleratus is discussed theoretically and investigated experimentally. Ion-pair chromatography with volatile ammonium perfluoroheptanoate was used for the separation of tetrodotoxin and 4,9-anhydrotetrodotoxin. The postcolumn reaction was based on the tetrodotoxin conversion to a quinazoline fluorescent compound under strong alkaline conditions. All postcolumn parameters were optimized that affected the sensitivity, dispersion, and stability. Helically coiled and knitted open tubular reactors composed of polyetheretherketone were constructed and characterized in detail. The performance of these reactors was evaluated on the basis of sensitivity and dispersion. Their optimal design is reported. The knitted reactors were more efficient than the relevant helically coiled reactors when higher reaction times are required. A 1500-mu L polyetheretherketone knitted coil with 0.010 internal diameter was optimum exhibiting higher pressure tolerances than Teflon coils. The HPLC postcolumn reaction method was evaluated in terms of linearity, sensitivity, accuracy, precision, and ruggedness. The linear dynamic ranges for tetrodotoxin and 4,9-anhydrotetrodotoxin were 40-3000 and 80-3000 ppb, respectively. The limits of detection and quantification were 12 and 41 ppb, respectively, for tetrodotoxin and 26 and 85 ppb, respectively, for 4,9-anhydrotetrodotoxin. The accuracy was evaluated by recovery measurements and the values for tetrodotoxin were between 90.7 and 93.6%. The use of a volatile perfuorocarboxylic acid as an ion-pair reagent allows confirmation of analytes in sample matrix by liquid chromatography tandem mass spectrometry using identical mobile phase conditions.
机译:理论上并通过实验研究了用于高效液相色谱(HPLC)的高性能液相色谱(HPLC)测定铁卵巢菌菌裂变中的四抗毒素的荧光反应体系。使用挥发性铵的离子对色谱法用于分离四曲蛋白和4,9- anhydrootetrodotoxin。后瘤反应基于在强碱条件下对喹唑啉荧光化合物的四曲毒素转化。所有PostColumn参数都经过优化,影响灵敏度,色散和稳定性。由聚醚醚酮由聚醚醚酮组成的螺旋盘绕和针织的开放管式反应器进行详细构建和表征。基于敏感性和分散评估这些反应器的性能。报告了他们的最佳设计。当需要更高的反应时间时,针织反应器比相关的螺旋盘式反应器更有效。具有0.010内径的1500μl聚醚醚酮编织线圈,其具有比Teflon线圈更高的压力容差。在线性,灵敏度,准确性,精度和坚固性方面评估了HPLC后抑制反应方法。四抗毒素和4,9- anhydrootetrodotoxin的线性动态范围分别为40-3000和80-3000ppb。对于4,9-Anhydrootetrodotoxin,检测和定量的极限分别为四胞毒素和26和85ppb,分别为四胞毒素和26和85ppb。通过恢复测量评价的精度,四抗毒素的值介于90.7和93.6%之间。使用挥发性灌注羧酸作为离子对试剂允许使用相同的流动相条件通过液相色谱串联质谱法确认样品基质中的分析物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号