Comparison of variability in breast density assessment by BI-RADS category according to the level of experience

机译:根据经验水平的Bi-Rads类别对乳房密度评估的可变性的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Background Only few studies have assessed variability in the results obtained by the readers with different experience levels in comparison with automated volumetric breast density measurements. Purpose To examine the variations in breast density assessment according to BI-RADS categories among readers with different experience levels and to compare it with the results of automated quantitative measurements. Material and Methods Density assignment was done for 1000 screening mammograms by six readers with three different experience levels (breast-imaging experts, general radiologists, and students). Agreement level between the results obtained by the readers and the Volpara automated volumetric breast density measurements was assessed. The agreement analysis using two categories—non-dense and dense breast tissue—was also performed. Results Intra-reader agreement for experts, general radiologists, and students were almost perfect or substantial (k?=?0.74–0.95). The agreement between visual assessments of the breast-imaging experts and volumetric assessments by Volpara was substantial (k?=?0.77). The agreement was moderate between the experts and general radiologists (k?=?0.67) and slight between the students and Volpara (k?=?0.01). The agreement for the two category groups (nondense and dense) was almost perfect between the experts and Volpara (k?=?0.83). The agreement was substantial between the experts and general radiologists (k?=?0.78). Conclusion We observed similar high agreement levels between visual assessments of breast density performed by radiologists and the volumetric assessments. However, agreement levels were substantially lower for the untrained readers.
机译:背景技术与自动体积乳房密度测量相比,少数研究在具有不同经验水平的读者获得的结果中评估了变化。目的在于具有不同体验水平的读者中的Bi-RADS类别的乳房密度评估的变化,并将其与自动定量测量结果进行比较。材料和方法密度分配为1000个筛选乳房X线照片,六个读者,具有三种不同的体验水平(母乳摄像机,一般放射科医师和学生)。评估读者和Volpara自动体积乳收密度测量的结果之间的协议水平。还进行了使用两类 - 非密集和致密乳房组织的协议分析。结果读者内专家,一般放射科医师和学生的协议几乎是完美的或大量的(K?= 0.74-0.95)。母乳成像专家的视觉评估与Volpara的体积评估之间的协议很大(K?= 0.77)。该协议在专家和一般放射科医生之间适中(K?= 0.67),学生和Valpa8之间的轻微(K?= 0.01)。两个类别群体(Nondense和密集)的协议几乎完美地在专家和Valpa(K?= 0.83)之间。该协议在专家和一般放射科学家之间存在大幅度(K?= 0.78)。结论我们观察了放射科学患者和体积评估的乳房密度的视觉评估之间的类似高度协议水平。但是,未经培训的读者,协议水平大幅降低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号