首页> 外文期刊>Acta Radiologica >Advanced monoenergetic reconstruction technique in dual-energy computed tomography for evaluation of vascular anatomy before adrenal vein sampling
【24h】

Advanced monoenergetic reconstruction technique in dual-energy computed tomography for evaluation of vascular anatomy before adrenal vein sampling

机译:双能计算断层扫描中的先进单体重建技术评估肾上腺静脉抽样前的血管解剖学

获取原文
获取原文并翻译 | 示例
       

摘要

Background In adrenal vein sampling, selecting the right adrenal vein is technically difficult and it is important to evaluate the right adrenal vein anatomy before adrenal vein sampling. The advanced monoenergetic reconstruction technique has recently become available and we hypothesized that this technique may be useful. Purpose To evaluate the usefulness of the advanced monoenergetic reconstruction technique in dual-energy computed tomography (CT; advanced monoenergetic images) for evaluation of vascular anatomy before adrenal vein sampling. Material and Methods Twenty-one patients underwent three-phase (20, 30, and 70 s) contrast-enhanced CT before adrenal vein sampling. Advanced monoenergetic images were reconstructed at 40 keV and analyzed objectively and subjectively in comparison with the standard 120-kVp images. As objective evaluation, the signal-to-noise ratio and contrast-to-noise ratio of the right adrenal vein were assessed. As subjective evaluation, two radiologists assessed the delineation of the right adrenal vein using a 5-point Likert scale (1 = poor, 5 = excellent). Furthermore, the technical success rate of adrenal vein sampling and procedure time were also evaluated. Results There was no difference in the signal-to-noise ratio between the two groups. The contrast-to-noise ratios of the right adrenal vein of advanced monoenergetic images were higher than those of the standard images (P < 0.05). The Likert scores of advanced monoenergetic images were higher than those of the standard images (P < 0.05). The technical success rate of adrenal vein sampling was 95% (20/21) and the median of procedure time was 103 min (range = 59-197 min). Conclusion Advanced monoenergetic imaging appears to be useful in the delineation of the right adrenal vein before adrenal vein sampling.
机译:背景技术在肾上腺静脉抽样中,选择右肾上腺静脉在技术上困难,重要的是在肾上腺静脉抽样之前评估右肾上腺静脉解剖学。先进的单齿重建技术最近可用,我们假设该技术可能是有用的。目的是评估双能计算断层扫描(CT;晚期单核图像)晚期单能重建技术的用途进行肾上腺静脉抽样前评价血管解剖学。材料和方法二十一名患者在肾上腺静脉采样之前接受三相(20,30和70级和70秒)对比度增强CT。高级单齿性图像在40keV中重建,并与标准120 kVP图像相比,客观地和主观地分析。作为客观评价,评估右肾上腺静脉的信噪比和对比度噪声比。作为主观评价,两个放射科医生使用5点李克特量表评估右肾上腺静脉的描绘(1 =差,5 =优异)。此外,还评估了肾上腺静脉抽样和程序时间的技术成功率。结果两组之间的信噪比没有差异。高级单体图像的右肾上腺静脉的对比度差异高于标准图像(P <0.05)。高级单齿性图像的李克特分数高于标准图像(P <0.05)。肾上腺静脉抽样的技术成功率为95%(20/21),程序时间的中位数为103分钟(范围= 59-197分钟)。结论晚期单元成像似乎在肾上腺静脉采样前的右肾上腺静脉划清烂中有用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号