Influence of abutment material on peri‐implant soft tissues in anterior areas with thin gingival biotype: a multicentric prospective study

机译:邻近地区静脉静脉软组织对薄牙龈生物型的影响:多中心前瞻性研究

获取原文
获取原文并翻译 | 示例

摘要

Abstract Purpose The aim of the present clinical trial was to analyze, through spectrophotometric digital technology, the influence of the abutment material on the color of the peri‐implant soft tissue in patients with thin gingival biotype. Material and methods Thirty‐seven patients received an endosseous dental implant in the anterior maxilla. At time of each definitive prosthesis delivery, an all‐ceramic crown has been tried on gold, titanium and zirconia abutment. Peri‐implant soft‐tissue color has been measured through a spectrophotometer after the insertion of each single abutment. Also facial peri‐implant soft‐tissue thickness was measured at the level of the implant neck through a caliper. A specific software has been utilized to identify a standardized tissue area and to collect the data before the statistical analysis in Lab* color space. Δ E parameters of the selected abutments were tested for correlation with mucosal thickness. Pearson correlation test was used. Results Only 15 patients met the study inclusion criteria on peri‐implant soft‐tissue thickness. Peri‐implant soft‐tissue color was different from that around natural teeth, no matter which type of restorative material was selected. Measurements regarding all the abutments were above the critical threshold of Δ E 8.74 for intraoral color distinction by the naked eye. The Δ E mean values of gold and zirconium abutments were similar (11.43 and 11.37, respectively) and significantly lower ( P? = ? 0.03 and P? = ? 0.04, respectively) than the titanium abutment (13.55). In patients with a facial soft‐tissue thickness ≤2?mm, the Δ E mean value of gold and zirconia abutments was significantly lower than that of titanium abutments ( P? = ? 0.03 and P? = ? 0.04, respectively) and much more close to the reference threshold of 8.74. Conclusions For peri‐implant soft tissue of ≤2?mm, gold or zirconia abutments could be selected in anterior areas treatment. Moreover, the thickness of the peri‐implant soft tissue seemed to be a crucial factor in the abutment impact on the color of soft tissues with a thickness of ≤2?mm.
机译:摘要目的目前临床试验的目的是通过分光光度数字技术分析邻接材料对薄牙龈生物型患者的患者皮肤软组织颜色的影响。材料和方法三十七名患者在前颌骨上接受了内骨牙科植入物。在每个明确的假体递送时,已经尝试过金,钛和氧化锆邻接的全陶瓷冠。通过分光光度计在插入每个邻接后通过分光光度计测量PERI植入软组织颜色。还通过卡钳在植入物颈部的水平下测量面部植入物软组织厚度。已经利用特定软件来识别标准化的组织区域并在实验室中的统计分析之前收集数据。测试所选支座的ΔE参数以与粘膜厚度相关。使用Pearson相关试验。结果仅15名患者均符合Peri-incomant软组织厚度的研究纳入标准。无论选择哪种恢复材料,Peri-incomant软组织颜色都不同于天然牙齿。关于所有基台的测量高于δe8.74的临界阈值,用于通过肉眼进行口腔内颜色区别。黄金和锆基邻托管的δe平均值(分别为11.43和11.37)并且显着降低(p?= 0.03和p?= 0.04),而不是钛基台(13.55)。在面部软组织厚度≤2Ω·mm的患者中,黄金和氧化锆基台的δe平均值显着低于钛基台(P?= 0.03和P?= 0.04)等等接近8.74的参考阈值。对于≤2Ω·mm,金或氧化锆基台的Peri植入软组织的结论可以在前部区域进行。此外,PERI-植入软组织的厚度似乎是对邻接对软组织颜色的关键因素,厚度为≤2Ωmm。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号