首页> 外文期刊>Blood Pressure Monitoring >Validation of noninvasive oscillometric blood pressure 2020 up pressure upper arm blood pressure monitoring technology according to the European Society of Hypertension International Protocol revision 2010
【24h】

Validation of noninvasive oscillometric blood pressure 2020 up pressure upper arm blood pressure monitoring technology according to the European Society of Hypertension International Protocol revision 2010

机译:验证非侵入式示波器血压2020压力上臂血压监测技术根据欧洲高血压国际协议修订版2010

获取原文
获取原文并翻译 | 示例
           

摘要

To validate noninvasive oscillometric blood pressure (NIBP) 2020 up pressure (UP) upper arm blood pressure (BP) monitoring technology according to the European Society of Hypertension International Protocol revision 2010 (ESH-IP revision 2010). According to the protocol, 33 participants were included. NIBP2020 UP technology was integrated into the BP+ host device, and common upper arm cuffs were used. The study included patients from ambulatory Hypertension Units. The validation procedure was performed exactly as required by ESH-IP revision 2010. Overall, 57.6% of the study population was female. Mean age was 45.5 +/- 16.3 years. Mean systolic blood pressure (SBP) was 142.9 +/- 30.6 mmHg and mean diastolic blood pressure (DBP) was 89.0 +/- 24.9 mmHg. The number of measurements within the difference range of up to 5 mmHg was 86 for SBP and 92 for DBP; 95 measurements of SBP and 99 of DBP were within the difference range of up to 10 mmHg, and 97 measurements of SBP and 99 measurement of DBP were in the difference range of up to 15 mmHg. Mean observer-test device differences were -0.2 +/- 4.6 mmHg for SBP and 0.6 +/- 3.1 mmHg for DBP. At least two observer-test differences were up to 5 mmHg for SBP in all participants and for DBP in 31 participants. All participants had at least one measurement with an observer-test difference of up to 5 mmHg for SBP and DBP. The NIBP2020 UP technology integrated into the BP+ host device using common upper arm cuffs passed the validation criteria according to the ESH-IP revision 2010. Copyright (c) 2019 Wolters Kluwer Health, Inc. All rights reserved.
机译:根据欧洲高血压国际协议修订版2010(ESH-IP Revision 2010),验证非侵入式示波器血压(NIBP)2020上臂血压(BP)监测技术。根据“议定书”,包括33名参与者。 NIBP2020 UP技术已集成到BP +主机设备中,并使用公共上臂袖口。该研究包括患者免受动静高血压单位。验证程序完全根据ESH-IP修订版本的要求进行2010年。总体而言,57.6%的研究人口是女性。平均年龄为45.5 +/- 16.3岁。平均收缩压(SBP)为142.9 +/- 30.6 mmHg,平均舒张压(DBP)为89.0 +/- 24.9 mmHg。对于DBP的SBP和92,可达5mmHg的差异范围内的测量值为86; 95 DBP的SBP和99的测量值在高达10mmHg的差异范围内,SBP和99个DBP测量的97次测量值高达15mmHg。平均观察者 - 试验装置差异为-0.2 +/- 4.6mmHg,用于DBP的0.6 +/- 3.1 mmHg。所有参与者中的SBP至少有两个观察者测试差异高达5 mmHg,并在31名参与者中进行DBP。所有参与者至少有一个测量,具有达到5mmHg的观察者测试差,用于SBP和DBP。使用公共上臂袖口集成到BP +主机设备中的NIBP2020 UP技术通过了验证标准根据ESH-IP修订版2010。版权所有(C)2019 Wolters Kluwer Health,Inc。保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com