RATIONALE AND OBJECTIVES: The aim of this study was to preliminarily assess the performance of a new, resonance-frequency electrical impedance spectroscopy (REIS) system in identifying young women who were recommended to undergo breast biopsy following imaging. MATERIALS AND METHODS: A seven-probe REIS system was designed and assembled and is currently being prospectively tested. During examination, contact is made with the nipple and six concentric points on the breast skin. Signal sweeps are performed, and outputs ranging from 200 to 800 kHz at 5-kHz intervals are recorded. An initial set of 140 patients, including 56 who eventually had biopsies, 63 who had negative results on screening mammography, and 21 recalled for additional imaging but later determined to have negative results, was used. An initial set of 35 features, 33 representing impedance signal differences between breasts and two representing participant age and average breast density, was assembled and reduced by a genetic algorithm to 14. The performance of an artificial neural network-based classifier was assessed using a case-based leave-one-out method. RESULTS: The substantially greater asymmetry between signals of mirror-matched regions ascertained from biopsy ("positive") compared to nonbiopsy ("negative") cases resulted in an artificial neural network classifier performance (area under the curve) of 0.830 +/- 0.023. At 90% specificity, this classifier, optimized for "recommendation for biopsy" rather than "cancer," detected 30 REIS-positive cases (54%), including six of nine (67%) actual cancer cases and six of nine women (67%) recommended for surgical excision of high-risk lesions. CONCLUSIONS: Asymmetry in impedance measurements between bilateral breasts may provide valuable discriminatory information regarding the presence of highly suspicious imaging-based findings.
机译:理由和目的:这项研究的目的是初步评估新的共振频率电阻抗谱(REIS)系统在识别建议进行影像学检查后进行乳房活检的年轻妇女中的性能。材料与方法:设计并组装了一个七探针REIS系统,目前正在进行前瞻性测试。在检查过程中,乳头与乳房皮肤上的六个同心点接触。执行信号扫描,并以5 kHz的间隔记录200至800 kHz的输出范围。使用了最初的140例患者,其中包括56例最终进行活组织检查,63例在乳腺钼靶筛查中显示阴性结果,以及21例被召回进行其他影像学检查,但后来确定具有阴性结果。最初的35个特征集,其中33个代表乳房之间的阻抗信号差异,两个代表参与者年龄和平均乳房密度,并通过遗传算法缩减为14个。基于案例的评估基于人工神经网络的分类器的性能的留一法。结果:与非活检(“阴性”)相比,活检(“阳性”)确定的镜面匹配区域信号之间的不对称性明显更大,导致人工神经网络分类器性能(曲线下面积)为0.830 +/- 0.023 。以90%的特异性,此分类器针对“活检推荐”而非“癌症”进行了优化,共检测到30例REIS阳性病例(54%),其中包括9例(67%)实际癌症病例中的6例和9例女性(67人中67例) %)建议用于高风险病变的手术切除。结论:双侧乳房之间的阻抗测量中的不对称性可能会提供有关基于高度可疑影像学检查结果的有价值的歧视性信息。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号